We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ0,8-5GM-N-10M
Part number
106336
Type
Inductive sensor
Description
Inductive sensor NJ0,8-5GM-N-10M
Stock availability:
On request
If you are pursuing Pepperl+Fuchs NJ0,8-5GM-N-10M 106336, get in touch with FAMAGA, the world's principle company of factory-made equipment. Our company has progressed for more than ten years - these are years of experience, which are represented in the quality of products and private attention to each user. We respect everyone, who engaged with us - hence, our regular consumers accept the most flexible purchase conditions and discounts on the manufacturing equipment market. At this moment, there are more than 4 thousand such consumers, and we constantly compose new agreements. More than 750 transactions are made per day, because FAMAGA works all over the globe Germany, United Kingdom, Denmark, Tanzania, San Marino, Bosnia and Herzegovina, Cyprus, Djibouti, Nicaragua, Chile, Lithuania, Canada, Liechtenstein, South Sudan, Nepal, Netherlands, Tajikistan, Luxembourg, Qatar, Burkina Faso, Azerbaijan, Madagascar, Morocco, Peru, Ireland, Malaysia, Senegal, Andorra, Albania, Jamaica, Norway, Yemen, Czech Republic, Dominica, Greece, Estonia, Mauritania, Angola, Suriname, Syria, Panama, Latvia, Pakistan, Serbia, Mali, Mexico, Antigua and Barbuda, Guatemala, Cameroon. A advanced logistics network and a partnership network allow us to dispatch our goods anywhere in the earth quickly without disreputing product quality.
A specific source of dignity for FAMAGA is its workers, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the range of machine made streamlined equipment.
All outcomes from FAMAGA are verified - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been provided, and this quantity is ascending every day. We are happy that customers choose FAMAGA again and again, and we are pleased to make more progressive and technologically modern industrial equipment so as to stay on the top.
To get some advice or make a request, get in touch with us or write to the online chat on our site. You can also dispatch a list of the needful equipment to the email of organization - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 0.8 mm | |
Installation | flush | |
Assured operating distance | 0 ... 0.65 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | typ. % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | &ge, 3 mA at nominal voltage | |
Measuring plate detected | &le, 1 mA at nominal voltage | |
Functional safety related parameters | ||
MTTFd | 1050 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 10 m | |
Core cross-section | 0.14 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Cable | ||
Cable diameter | 2.6 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 0,8-5GM-N... | |
Effective internal capacitance | max. 30 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ0,8-5GM-N... | |
Effective internal capacitance | max. 30 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ0,8-5GM-N... | |
Effective internal capacitance | max. 30 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |