We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
K-LB-1.30
Part number
098908
Type
Module
Description
Stock availability:
On request
Product Description |
---|
2-line protection |
General specifications | ||
---|---|---|
Number of protected signal lines | 2 | |
Topology | non-grounded | |
Electrical specifications | ||
Connection | protected area: terminals 7, 8 unprotected area: terminals 1, 2 | |
Rated current | 250 mA | |
Leakage current | < 5 µ,A at 24 V and 25 °C (77 °F) , line-line | |
Nominal voltage | 24 V DC | |
Maximum continuous operating voltage | 30 V DC | |
Series resistance | < 0.5 &Omega, per line | |
Impulse rating | 10 kV/5 kA (category C2) 2 kV/2 kA (category D1) | |
Impulse discharge current (10/350 µ,s) | 2 kA per line (2x) | |
Nominal discharge current (8/20 µ,s) | 5 kA per line (10x) | |
Rated surge current (8/20 µ,s) | 10 kA per line (1x) | |
Total discharge current (8/20 µ,s) | 20 kA (1x) | |
Voltage protection level | max. 75 V line-line for nominal discharge current In max. 1.2 kV line-earth for nominal discharge current In | |
Impulse reset time | < 30 ms | |
Insertion loss | &le, 0.05 dB, at 0 ... 4 kHz, in 600 &Omega,-System &le, 3 dB, at 0 ... 174 kHz, in 100 &Omega,-System | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Conformity | ||
Degree of protection | IEC 60529:2013 | |
Surge protective devices for low voltage | EN 61643-21:2001+A1:2009+A2:2013 IEC 61643-21:2001+A1:2008+A2:2012 | |
Operating conditions | ||
Installation conditions | ||
Mounting location | indoor | |
Ambient conditions | ||
Ambient temperature | -30 ... 80 °C (-22 ... 176 °F) For usage in hazardous area observe EC-type examination certificate. | |
Relative humidity | 5 ... 95 % | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross-section | 2 x 2.5 mm2 | |
Mass | approx. 100 g | |
Dimensions | 12.5 x 115 x 110 mm (0.5 x 4.5 x 4.3 inch) | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | PTB 00 ATEX 2176 X | |
Marking | II 2(1)G Ex ia IIC T6/T5/T4 | |
Temperature class | T6 for ambient temperature &le, 50 °C T5 for ambient temperature &le, 70 °C T4 for ambient temperature &le, 80 °C | |
Voltage | 30 V | |
Current | 250 mA | |
Internal capacitance | negligible | |
Internal inductance | 200 µ,H | |
Certificate | PF 16 CERT 4065 X | |
Marking | II (3)D [Ex ic Dc] IIIC | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0187 (cCSAus) | |
IECEx approval | ||
IECEx certificate | IECEx BAS 14.0010X | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |