Module VBA-4E3A-G20-ZEL/M1L-P6 Pepperl+Fuchs 291127
Module VBA-4E3A-G20-ZEL/M1L-P6 Pepperl+Fuchs 291127

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

VBA-4E3A-G20-ZEL/M1L-P6 291127 Pepperl+Fuchs Module

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

VBA-4E3A-G20-ZEL/M1L-P6

Part number

291127

Type

Module

Description

  • A/B slave with extended addressing possibility for up to 62 slaves
  • Inputs for 3-wire sensors
  • Outputs for DC roller motors (drum motors)
  • Connection of motors and sensors via M8 connectors
  • Configurable start/stop ramps
  • Communication monitoring
  • Power supply of the inputs and outputs from the external auxiliary voltage
  • Function display for bus, external auxiliary voltage, in- and outputs
  • Cable piercing method with gold plated contact pins

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications VBA-4E3A-G20-ZEL/M1L-P6 291127

The AS-Interface connecting module is a field module with two sensor inputs and two electronic outputs for controlling DC roller motors of the type Interroll EC310 and Rulmeca BL3 or compatible. The compact housing can be installed directly in support profiles or conduits. The connection to the AS-Interface network and power supply is made using the AS-Interface flat cable and insulation-piercing technology. The pivoted flat cable guide is secured using a snap fit. No tools are required. The sensor inputs and motor outputs are connected via cable outputs with M8 round plug connectors (inputs 4-pole female cordset with knurled thumb screw, outputs 5-pole snap-on female cordset). Power for the inputs and motors is provided by the external auxiliary voltage UAUX. The current switching state of the sensor inputs is indicated by the IN LEDs. The FUSE LEDs show that the power supply is applied to both motors. The MOT LEDs indicate when the motors are in operation (stop/operation). The DIR LED indicates the status of the rotation signal. The activation of the fault signal by a motor is displayed with the ERR LEDs. The motors can be switched on and off individually by means of AS-Interface databits D0 and D1. D2 controls the rotation signal. The AS-Interface parameters P0 ... P2 select the voltage for the speed signal. The rotation and speed apply to both motors. A start/stop ramp can be set for the speed signal for the controlled acceleration and stopping of the motors. The ramp duration can be selected from eight default values and can be configured over a defined sequence of data and parameters. The ramp selected in this way is saved permanently and is activated automatically after each power-on. The number of the ramp is displayed by a short flash of the ERR2, IN1, and IN2 LEDS in binary code. If the ramp number is set as 0 (no ramp), the six LEDs MOT1 to IN2 flash to show this. The ramp is not effective if the rotation signal is switched while the motor is running. In other words, the reversal of rotation direction occurs immediately. Note: The communication monitor of the module deactivates the outputs if there is no communictaion between the AS-Interface and the module for more than 40 ms. The IN1 and IN2 inputs suppress impulses of less than than 2 ms. A signal indicating an overload of the input supply , an overload of the speed signal, or the absence of the external auxiliary voltage is also transmitted to the AS-Interface master via the peripheral fault function. Communication via the AS-Interface continues.

Features VBA-4E3A-G20-ZEL/M1L-P6 291127

Product Description
G20 motor control module for Interroll EC310 and EC5000, Rulmeca BL3 and Itoh Denki PM500XK
General specifications
Slave typeA/B slave
AS-Interface specificationV3.0
Required master specification&ge, V2.1
UL File NumberE223772 For use in NFPA 79 Applications only
MTBF98 a
Compatible roller motorsInterroll EC310, Interroll EC5000, Itoh Denki PM500XK, Rulmeca BL3
Indicators/operating means
LED FAULTerror display, LED red red: communication error or address is 0 red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing
LED ERRMotor fault: 2 LED yellow
LED PWRAS-Interface voltage, green LED green: voltage OK green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing
LED AUXext. auxiliary voltage UAUX, dual LED green/red green: voltage OK red: reverse voltage
LED INswitching state (input), 2 LED yellow
LED FUSEMotor power supply, 2 green LEDs
LED DIRMotor rotation direction, yellow LED
LED MOTMotor active, 2 yellow LEDs
Electrical specifications
Auxiliary voltage (output)18 ... 30 VDC PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current&le, 35 mA
Input
Number/Type2 Inputs for 3-wire sensors (PNP), DC
Supplyfrom external auxiliary voltage UAUX
Current loading capacity500 mA , overload and short-circuit protected
Input current&le, 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 0 (undamped) &le, 0.5 mA 1 (damped) &ge, 2.0 mA
Signal delay< 1 ms (input/AS-Interface)
Input filter2 ms
Output
Number/Type2 outputs for DC roller motors (MOT1, MOT2)
Supplyfrom external auxiliary voltage UAUX
Currentmax. 5 A per motor
Overload protectionfuse , I2t = 5.56 A2s
Velocity signal1.4 &hellip, 13 V at no-load Ri = 5.6 k&Omega,, RLOAD &ge, 35 k&Omega, Control via parameter P2:0
Rotation direction signalOff / &ge, (UAUX - 1.0 V) at no-load Ri = 5.6 k&Omega,, RLOAD &ge, 5 k&Omega, AS-Interface data bit D2 = 0: UD = Off
Motor faultDigital input NPN, U0 = 3.3 V, Ri = 52 k&Omega, 0 (no error) &ge, 40 µ,A 1 (error) &le, 30 µ,A
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
InputEN 61131-2:2007
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Programming instructions
ProfileS-7.A.E
IO code7
ID codeA
ID1 code6
ID2 codeE
Data bits (function via AS-Interface) input output
D0 MOT1 fault MOT1 operation
D1 MOT2 fault MOT2 operation
D2 IN1 MOT1/MOT2 rotation direction
D3 IN2 -
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Degree of protectionIP54 according to EN 60529
ConnectionAS-Interface, AUX: Insulation piercing technology Yellow flat cable/black flat cable Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104 Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded) Matching connector: LM004-Gx1-A or similar Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded). Matching connector: NM005-Sx1-B or similar
Mass220 g
Mounting2 clips with &empty, 8 mm drill hole
Cable length0.35 m
NoteThe flat cable routing is designed for 100 actuation cycles