Inductive sensor NRB8-18GM40-E2-IO-C-V1 Pepperl+Fuchs 306533-0005
Inductive sensor NRB8-18GM40-E2-IO-C-V1 Pepperl+Fuchs 306533-0005

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

NRB8-18GM40-E2-IO-C-V1 306533-0005 Pepperl+Fuchs Inductive sensor

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NRB8-18GM40-E2-IO-C-V1

Part number

306533-0005

Type

Inductive sensor

Description

  • 8 mm flush
  • Reduction factor = 1
  • Magnetic field resistant
  • Weld Immune
  • IO-link interface for service and process data
  • Switch point mode or window mode can be set
  • Switching function, stability alarm and pulse extension can be set

Stock availability:

On request

117.57 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NRB8-18GM40-E2-IO-C-V1 306533-0005

Reduction factor 1 sensors reliably detect different metals with the same switch state. The integrated IO-Link interface enables clear identification of the sensor and diagnosis of the sensor condition. When using the sensor, parameters and operating modes can be optimally configured specifically for the intended application. In addition to setting the switching function and a pulse extension, the user can select either switch point mode or window mode in combination with a stability alarm. In switch point mode, the stability alarm signals the detection of an object in the area between the assured operating distance and operating distance sn. In window mode, it signals the detection of an object below the window between operating distance sn and the nearest operating distance. A stability alarm is displayed to the user via a flashing LED and process data.

Features NRB8-18GM40-E2-IO-C-V1 306533-0005

General specifications
Switching functionNormally open/closed (NO/NC) programmable
Output typePNP
Rated operating distance8 mm (factory setting)
Near operating distance5 mm (can be activated by software)
Installationflush
Output polarityDC
Assured operating distance0 ... 6.48 mm
Reduction factor rAl 1
Reduction factor rCu 1
Reduction factor r304 1
Reduction factor rSt37 1
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 1500 Hz (switch point mode) 0 ... 150 Hz (window mode, switch point mode with stability alarm)
Hysteresistyp. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le, 0.5 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA typ. 60 µ,A at 25 °C
No-load supply current&le, 15 mA
Time delay before availabilitymax. 150 ms
Constant magnetic field200 mT
Alternating magnetic field200 mT
Status indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd362 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Interface
Interface typeIO-Link ( via C/Q = pin 4 )
Transfer rateCOM 2 (38.4 kBaud)
IO-Link Revision1.1
Min. cycle time2.3 ms
Process data widthProcess data input (control system side): 2 Bit Process data output (control system side): none
SIO mode supportyes
Device ID0x201112 (2101522)
Compatible master port typeA
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
Protection classII
Rated insulation voltage60 V
Rated impulse withstand voltage800 V
UL approvalcULus Listed, General Purpose Class 2 power source
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialBrass, PTFE coated
Sensing facePPS
Degree of protectionIP67
Mass54 g
Factory settings
Default settingoperating mode = switch point mode with stability alarm switching function = Normally open (NO) switching distance = 8 mm
General information
Scope of delivery2 self locking nuts in scope of delivery