Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ5-18GM50-E2-5M-3G-3D
Part number
310833
Type
Inductive sensor
Description
Stock availability:
On request
If you are pursuing Pepperl+Fuchs NJ5-18GM50-E2-5M-3G-3D 310833, catch up with FAMAGA, the world's main provider of manufacturing equipment. Our company has functioned for more than ten years - these are cycles of experience, which are outlined in the quality of spare parts and private attention to each purchaser. We esteem everyone, who joined with us - thus, our regular consumers procure the most beneficial purchase forms and discounts on the machine made streamlined equipment market. At present, there are more than 4 thousand such clients, and we constantly compose new agreements. More than 700 purchases are terminated per day, because FAMAGA works all over the planet Germany, United Kingdom, Morocco, Czech Republic, Mexico, Nigeria, East Timor, Hungary, Brunei, Romania, Libya, China, Greece, Myanmar, Swaziland, Gambia, Antigua and Barbuda, Macedonia, Turkmenistan, Niger, Thailand, Mali, Zambia, Burundi, Cameroon, Guatemala, Ecuador, Belize, Croatia, India, Kenya, Bosnia and Herzegovina, Namibia, Israel, Kiribati, Argentina, Tunisia, Zimbabwe, Tonga, Lithuania, Ghana, Algeria. A advanced logistics chains and a partnership network assist us to conduct our goods anywhere in the planet on-time without disreputing product quality.
A particular source of good name for FAMAGA is its workers, each of whom contributes to our work. We request into our team only experts, who already have experience in the sphere of manufacturing equipment.
All items from FAMAGA are verified - we are responsible for the result of our work. Now, more than 10 million units of products have been delivered, and this bulk is ascending every day. We are happy that clients choose FAMAGA again and again, and we are pleased to make more exceptional and technologically advanced industrial equipment so as to stay on the top.
To inquire or order, contact us or write to the online chat on our site. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 5 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 4.05 mm | |
Actual operating distance | 4.5 ... 5.5 mm typ. 5 mm | |
Reduction factor rAl | 0.2 | |
Reduction factor rCu | 0.13 | |
Reduction factor r304 | 0.62 | |
Reduction factor rBrass | 0.26 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 2000 Hz | |
Hysteresis | 3 ... 15 typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le, 3 V | |
Voltage drop at IL | ||
Voltage drop IL = 200 mA, switching element on | 1 ... 2 V typ. 1.5 V | |
Operating current | &le, 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.01 mA | |
No-load supply current | &le, 15 mA | |
Time delay before availability | &le, 100 ms | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1504 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 5 m | |
Core cross-section | 0.5 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Gc (nA) , Dc | |
Equipment protection level Gc (nA) | ||
Type of protection | n | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF15CERT3754X | |
ATEX marking | II 3G Ex nA IIC T6 Gc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
Surge protection | The protection against transient overvoltage with amplitude U is realized. U = 500 V at 1.2/50 µ,s, 500 &Omega, | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 52 °C (125.6 °F) at UBmax = 30 V , IL = 100 mA : 54 °C (129.2 °F) at UBmax = 30 V , IL = 50 mA : 55 °C (131 °F) | |
Equipment protection level Dc | ||
Type of protection | Protection by enclosure tc | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF15CERT3774X | |
ATEX marking | II 3D Ex tc IIIC T80 °C Dc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-31:2014 | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output current IAmax , maximum analog output voltage UAmax | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 52 °C (125.6 °F) at UBmax = 30 V , IL = 100 mA : 54 °C (129.2 °F) at UBmax = 30 V , IL = 50 mA : 55 °C (131 °F) | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery | |
Use in the hazardous area | see instruction manuals |