  • Temperature range 0 ... 200 °C (0 ... 392 °F)

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NJ4-30GM-N-200-10M 304836

If you are seeking Pepperl+Fuchs NJ4-30GM-N-200-10M 304836, get in touch with FAMAGA, the world's main provider of streamlined equipment. Our company has functioned for more than ten years - these are years of experience, which are represented in the quality of merchandises and special attention to each purchaser. We respect everyone, who joined with us - therefore, our regular buyers procure the most flexible purchase conditions and discounts on the industrial equipment market. Today, there are more than 4500 such purchasers, and we constantly form new agreements. More than 650 affairs are settled per day, because FAMAGA supplies all over the globe . A well-developed logistics chains and a partnership network guide us to deliver our goods anywhere in the earth promptly without discrediting product quality.

A special source of repute for FAMAGA is its employees, each of whom contributes to our work. We invite into our team only professionals, who already have experience in the range of machine made streamlined equipment.

All items from FAMAGA are assured - we are responsible for the aftereffect of our work. Nowadays, more than 10 million units of products have been provided, and this number is rising every day. We are glad that customers choose FAMAGA again and again, and we strive to make more advanced and technologically developed industrial equipment so as keep on top of it.

To request or make a request, call us by phone or send a message to the online chat on our site. You can also dispatch a list of the needful equipment to the email of our company - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features NJ4-30GM-N-200-10M 304836

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance4 mm
Installationflush
Assured operating distance0 ... 3.04 mm
Reduction factor rAl 0.15
Reduction factor rCu 0.05
Reduction factor r304 0.55
Output type2-wire
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 1000 Hz
Hysteresis&le, 20 % at 200°C
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le, 1 mA
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature0 ... 200 °C (32 ... 392 °F)
Mechanical specifications
Connection typecable SIHF , 10 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePPS
Degree of protectionIP65
Cable
Bending radius> 10 x cable diameter
Noteamplifier -25°C...70°C 2 m PTFE cable between amplifier and oscillator
Data for application in connection with hazardous areas
Equipment protection levelGa , Gb , Da
Equipment protection level Ga
Type of protectionintrinsic safety
CE marking[*PD-Z02585A*]
Certificates
Appropriate typeNJ4-30GM-N-200...
ATEX certificatePTB 00 ATEX 2048 X
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga
StandardsEN 60079-0:2012+A11:2013 , EN 60079-11:2012
Effective internal capacitancemax. 70 nF A cable length of 10 m is considered.
Effective internal inductancemax. 100 µ,H A cable length of 10 m is considered.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. Refer to the relevant certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature, the effective inner reactances, and if applicable the surface temperature or the temperature class.
for ATEXat Ui = 16 V , Ii = 25 mA , Pi = 34 mW , at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , at Ui = 16 V , Ii = 76 mA , Pi = 242 mW
Equipment protection level Gb
Type of protectionintrinsic safety
CE marking[*PD-Z02585A*]
Certificates
Appropriate typeNJ4-30GM-N-200...
ATEX certificatePTB 00 ATEX 2048 X
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga
StandardsEN 60079-0:2012+A11:2013 , EN 60079-11:2012
Effective internal capacitancemax. 70 nF A cable length of 10 m is considered.
Effective internal inductancemax. 100 µ,H A cable length of 10 m is considered.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. Refer to the relevant certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature, the effective inner reactances, and if applicable the surface temperature or the temperature class. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , at Ui = 16 V , Ii = 76 mA , Pi = 242 mW
Equipment protection level Da
Type of protectionintrinsic safety
CE marking[*PD-Z02585A*]
Certificates
Appropriate typeNJ4-30GM-N-200...
ATEX certificatePTB 00 ATEX 2048 X
ATEX marking II 1D Ex ia IIIC T135°C Da
StandardsEN 60079-0:2012+A11:2013 , EN 60079-11:2012
Effective internal capacitancemax. 70 nF A cable length of 10 m is considered.
Effective internal inductancemax. 100 µ,H A cable length of 10 m is considered.
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. Refer to the relevant certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature, the effective inner reactances, and if applicable the surface temperature or the temperature class. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , at Ui = 16 V , Ii = 76 mA , Pi = 242 mW