Inductive sensor RC10-14-N3-Y110970 x2xGxxxD Pepperl+Fuchs 110970
Inductive sensor RC10-14-N3-Y110970 x2xGxxxD Pepperl+Fuchs 110970

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

RC10-14-N3-Y110970 x2xGxxxD 110970 Pepperl+Fuchs Inductive sensor

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

RC10-14-N3-Y110970 x2xGxxxD

Part number

110970

Type

Inductive sensor

Description

Inductive ring sensor RC10-14-N3-Y110970

Stock availability:

On request

215.4 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications RC10-14-N3-Y110970 x2xGxxxD 110970

If you are pursuing Pepperl+Fuchs RC10-14-N3-Y110970 x2xGxxxD 110970, call FAMAGA, the world's top supplier of industrial equipment. Our company has operated for more than ten years - these are cycles of experience, which are portrayed in the quality of outputs and particular attention to each buyer. We admire everyone, who cooperated with us - so, our regular customers receive the most acceptable purchase conditions and discounts on the manufacturing equipment market. At present, there are more than 4500 such purchasers, and we constantly form new agreements. More than 750 purchases are terminated per day, because FAMAGA works all over the earth . A well-built logistics system and a partnership network assist us to deliver our elements anywhere in the earth quickly without compromising product quality.

A special source of dignity for FAMAGA is its personnel, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the sphere of machine made streamlined equipment.

All products from FAMAGA are verified - we are responsible for the result of our work. At this moment, more than 10 million units of products have been provided, and this quantity is amounting every day. We are glad that users choose FAMAGA again and again, and we are happy to make more developed and technologically advanced industrial equipment so as keep on top of it.

To get some advice or order, get in touch with us or write to the online chat on our site. You can also direct a list of the needful equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features RC10-14-N3-Y110970 x2xGxxxD 110970

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR, bistable
Inside diameter10 mm
Measuring cylinder
Diameter2.5 mm
Length3 mm
Measuring cone
Material9S20K
Output type2-wire
Nominal ratings
Nominal voltage8 V
Hysteresistyp. 1 %
Reverse polarity protectionreverse polarity protected
Current consumption
Traverse B3 mA
Traverse A1 mA
Time delay before availability&le, 5 ms
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
Ambient conditions
Ambient temperature-20 ... 100 °C (-4 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.14 mm2
Housing materialPBT
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Gb
CE marking[*PD-Z02585A*]
ATEX marking II 2G Ex ia IIC T6&hellip,T1 Gb The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeRC10-...-N3...
Effective internal capacitancemax. 90 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 120 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
General information
Use in the hazardous areasee instruction manuals
Category2G