We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
PL3-F25-N4-K 123GxxxD
Part number
291801
Type
Inductive sensor
Description
Inductive sensor PL3-F25-N4-K
Stock availability:
On request
If you are inspecting Pepperl+Fuchs PL3-F25-N4-K 123GxxxD 291801, reach FAMAGA, the world's influential vendor of streamlined equipment. Our company has progressed for more than ten years - these are cycles of experience, which are illustrated in the quality of outputs and private attention to each user. We admire everyone, who joined with us - hence, our regular consumers accept the most acceptable purchase conditions and discounts on the manufacturing equipment market. Now, there are more than 4000 such clients, and we constantly sign new agreements. More than 750 contracts are concluded per day, because FAMAGA operates all over the earth Germany, United Kingdom, Montenegro, Ghana, South Africa, Monaco, Belgium, Egypt, Hungary, Burma, Burundi, Georgia, Mauritania, Chad, Kyrgyzstan, Paraguay, The Bahamas, Macedonia, Gambia, Azerbaijan, Malawi, Libya, South Sudan, Tonga, Japan, Togo, Bulgaria, Poland, Greece, Austria, Liechtenstein, Seychelles, Australia, Iran, Niger, Uruguay, Cape Verde, Denmark, Serbia, Senegal, Nigeria, Bangladesh, Benin. A well-elaborated logistics connection and a partnership network help us to deliver our goods anywhere in the globe immediately without disreputing product quality.
A special source of good name for FAMAGA is its staff members, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the direction of factory-made equipment.
All spare parts from FAMAGA are verified - we are responsible for the outcome of our work. At this moment, more than 10 million units of products have been supplied, and this quantity is ascending every day. We are proud that clients choose FAMAGA again and again, and we are eager to make more progressive and technologically advanced industrial equipment so as not to lower the bar.
To inquire or book, get in touch with us or send a message to the online chat on our official website. You can also forward a list of the desirable equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | 2 x normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 3 mm | |
Installation | flush mountable | |
Assured operating distance | 0 ... 2.43 mm | |
Actual operating distance | 2.7 ... 3.3 mm | |
Reduction factor rAl | 0.52 | |
Reduction factor rCu | 0.43 | |
Reduction factor r304 | 0.86 | |
Reduction factor rSt37 | 1 | |
Reduction factor rBrass | 0.54 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 100 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | yes | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | &ge, 3 mA at nominal voltage | |
Measuring plate detected | &le, 1 mA at nominal voltage | |
Time delay before availability | &le, 1 ms | |
Switching state indicator | LED, yellow | |
Valve status indicator | LED, yellow can be switched off by of DB1 | |
Functional safety related parameters | ||
MTTFd | 834 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Electromagnetic compatibility | NE 21:2007 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection (system side) | Cage tension spring terminals | |
Core cross-section (system side) | up to 2.5 mm2 | |
Connection (valve side) | Cage tension spring terminals | |
Core cross-section (valve side) | up to 2.5 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Mass | 91 g | |
Tightening torque, fastening screws | 0.3 Nm | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Ga , Gb , Gc (ic) , Mb | |
Equipment protection level Ga | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | PL...-F25...-N4... | |
ATEX certificate | TÜV 99 ATEX 1479 X | |
ATEX marking | II 1G Ex ia IIC T6...T1 Ga | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx TUN 17.0021X | |
IECEx marking | Ex ia IIC T6...T1 Ga | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. | |
for ATEX | at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 45 °C (113 °F) T5 : 55 °C (131 °F) T4 : 85 °C (185 °F) T3 : 85 °C (185 °F) T2 : 85 °C (185 °F) T1 : 85 °C (185 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 45 °C (113 °F) T5 : 55 °C (131 °F) T4 : 85 °C (185 °F) T3 : 85 °C (185 °F) T2 : 85 °C (185 °F) T1 : 85 °C (185 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 55 °C (131 °F) T4 : 85 °C (185 °F) T3 : 85 °C (185 °F) T2 : 85 °C (185 °F) T1 : 85 °C (185 °F) | |
for IECEx | at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) | |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. | |
Voltage | max. 32 V | |
Current | max. 240 mA | |
Internal capacitance | max. 10 nF | |
Internal inductance | max. 20 µ,H | |
Equipment protection level Gb | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | PL...-F25...-N4... | |
ATEX certificate | TÜV 99 ATEX 1479 X | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx TUN 17.0021X | |
IECEx marking | Ex ia IIC T6...T1 Ga | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) | |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. | |
Voltage | max. 32 V | |
Current | max. 240 mA | |
Internal capacitance | max. 10 nF | |
Internal inductance | max. 20 µ,H | |
Equipment protection level Gc (ic) | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
ATEX certificate | PF 13 CERT 2895 X | |
ATEX marking | II 3G Ex ic IIC T6&hellip,T1 Gc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 20 V , Ii = 25 mA , Pi = 34 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 25 mA , Pi = 64 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 20 V , Ii = 52 mA , Pi = 169 mW , T6 : 60 °C (140 °F) T5 : 75 °C (167 °F) T4 : 95 °C (203 °F) T3 : 95 °C (203 °F) T2 : 95 °C (203 °F) T1 : 95 °C (203 °F) | |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. | |
Voltage | max. 32 V | |
Current | max. 240 mA | |
Internal capacitance | max. 10 nF | |
Internal inductance | max. 20 µ,H | |
Equipment protection level Mb | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | PL...-F25...-N4... | |
IECEx certificate | IECEx TUN 17.0021X | |
IECEx marking | Ex ia I Mb | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 100 nF The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H The value is applicable for one sensor circuit. A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 15 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 15 V , Ii = 52 mA , Pi = 169 mW : 95 °C (203 °F) | |
Maximum values of the valve circuit | The value applies to each valve circuit. A cable length of 10 m is considered. | |
Voltage | max. 32 V | |
Current | max. 240 mA | |
Internal capacitance | max. 10 nF | |
Internal inductance | max. 20 µ,H | |
General information | ||
Use in the hazardous area | see instruction manuals |