Name
NBN40-U2K-N0
Part number
213837
Type
Inductive sensor
Description
Inductive sensor NBN40-U2K-N0
Stock availability:
On request
If you are questing Pepperl+Fuchs NBN40-U2K-N0 213837, call FAMAGA, the world's dominant supplier of factory-made equipment. Our company has existed for more than ten years - these are years of experience, which are symbolized in the quality of outcomes and private attention to each consumer. We admire everyone, who collaborated with us - so, our regular consumers receive the most beneficial purchase forms and discounts on the industrial equipment market. Nowadays, there are more than 4 thousand such consumers, and we constantly make new agreements. More than 750 transactions are made per day, because FAMAGA works all over the planet Germany, United Kingdom, Palestine, Belgium, Armenia, Papua New Guinea, Grenada, Benin, Russia, Turkey, Lithuania, Guyana, United Arab Emirates, Australia, Argentina, Paraguay, Sierra Leone, Guatemala, Azerbaijan, Chad, Jamaica, Macedonia, The Gambia, Niger, United States, Bosnia and Herzegovina, Syria, North Korea, Nepal, Ghana, Antigua and Barbuda, Mongolia, Albania, Tonga, Belarus, Chile, Jordan, Equatorial Guinea, Denmark, Kyrgyzstan, Switzerland, New Zealand, Mali. A well-built logistics bond and a partnership network cheer us to send our goods anywhere in the planet as soon as possible without disreputing product quality.
A particular source of honor for FAMAGA is its staff members, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the direction of industrial equipment.
All outcomes from FAMAGA are verified - we are responsible for the cause of our work. Now, more than 10 million units of products have been provided, and this number is rising every day. We are happy that customers choose FAMAGA again and again, and we are happy to make more progressive and technologically developed industrial equipment so as to stay on the top.
To get some advice or book, phone us or write a message to the online chat on our official website. You can also direct a list of the necessary equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 40 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 32.4 mm | |
Actual operating distance | 36 ... 44 mm | |
Reduction factor rAl | 0.31 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.74 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Switching frequency | 0 ... 150 Hz | |
Hysteresis | typ. 5 % | |
Reverse polarity protection | yes | |
Short-circuit protection | yes | |
Current consumption | ||
Measuring plate not detected | min. 2.2 mA | |
Measuring plate detected | &le, 1 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1415 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Electromagnetic compatibility | NE 21:2007 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0451 | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | screw terminals | |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
Core cross-section | up to 2.5 mm2 | |
Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
Housing material | PA | |
Sensing face | PA | |
Degree of protection | IP68 / IP69K | |
Mass | 225 g | |
Note | Tightening torque: 1.8 Nm (housing) | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NBN40-U.K-N0... | |
Effective internal capacitance | max. 105 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 300 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NBN40-U.K-N0... | |
Effective internal capacitance | max. 105 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 300 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Gc (ic) | ||
Certificate | PF 13 CERT 2895 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex ic IIC T6&hellip,T1 Gc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012, EN 60079-11:2012 Ignition protection category ic Use is restricted to the following stated conditions | |
Effective internal capacitance | max. 105 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 300 µ,H , A cable length of 10 m is considered. | |
Special conditions | ||
for Pi=34 mW, Ii=25 mA, T6 | 73 °C (163.4 °F) | |
for Pi=34 mW, Ii=25 mA, T5 | 88 °C (190.4 °F) | |
for Pi=34 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) | |
for Pi=64 mW, Ii=25 mA, T6 | 66 °C (150.8 °F) | |
for Pi=64 mW, Ii=25 mA, T5 | 81 °C (177.8 °F) | |
for Pi=64 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) | |
for Pi=169 mW, Ii=52 mA, T6 | 45 °C (113 °F) | |
for Pi=169 mW, Ii=52 mA, T5 | 60 °C (140 °F) | |
for Pi=169 mW, Ii=52 mA, T4-T1 | 89 °C (192.2 °F) | |
for Pi=242 mW, Ii=76 mA, T6 | 30 °C (86 °F) | |
for Pi=242 mW, Ii=76 mA, T5 | 45 °C (113 °F) | |
for Pi=242 mW, Ii=76 mA, T4-T1 | 74 °C (165.2 °F) | |
Equipment protection level Da | ||
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NBN40-U.K-N0... | |
Effective internal capacitance | max. 105 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 300 µ,H , a cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 3G |