We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
CJ4-12GK-N-Y235563
Part number
235563
Type
Capacitive sensor
Description
Capacitive sensor CJ4-12GK-N-Y235563
Stock availability:
On request
If you are inspecting Pepperl+Fuchs CJ4-12GK-N-Y235563 235563, communicate with FAMAGA, the world's key provider of manufacturing equipment. Our company has operated for more than ten years - these are ages of experience, which are represented in the quality of spare parts and particular attention to each buyer. We cherish everyone, who liased with us - hence, our regular clients get the most attractive purchase forms and discounts on the machine made streamlined equipment market. Nowadays, there are more than 3500 such purchasers, and we constantly arrange new agreements. More than 750 affairs are settled per day, because FAMAGA supplies all over the globe Germany, United Kingdom, Portugal, Colombia, Sudan, Paraguay, Philippines, Italy, Lebanon, Poland, Estonia, Netherlands, Singapore, Chad, Monaco, India, Slovenia, Indonesia, Guyana, Iceland, The Gambia, Swaziland, Haiti, Costa Rica, Afghanistan, Qatar, Samoa, China, Suriname, Syria, Laos, Kuwait, Moldova, United States, El Salvador, Ireland, Tajikistan, Albania, Latvia, Australia, Mexico, Panama, Djibouti, Sweden, Tanzania, Brunei, Benin, Switzerland, Uganda. A well-shaped logistics chains and a partnership network cheer us to deliver our goods anywhere in the globe with no delay without damaging product quality.
A particular source of pride for FAMAGA is its staff members, each of whom contributes to our work. We call into our team only specialists, who already have experience in the direction of factory-made equipment.
All outcomes from FAMAGA are ensured - we are responsible for the result of our work. Now, more than 10 million units of products have been provided, and this bulk is rising every day. We are pleased that buyers choose FAMAGA again and again, and we are glad to make more progressive and technologically modern industrial equipment so as keep on top of it.
To inquire or order, phone us or write a message to the online chat on our official website. You can also forward a list of the desirable equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | NAMUR | |
Rated operating distance | 4 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 2.88 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Installation conditions | ||
A | 20 mm | |
B | 80 mm | |
C | 12 mm | |
F | 70 mm | |
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Operating voltage | 7 ... 12 V | |
Switching frequency | 0 ... 1 Hz | |
Current consumption | ||
Measuring plate not detected | &le, 1 mA | |
Measuring plate detected | &ge, 2.4 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 55 mm with Connector, 99-3431-216-04, Binder | |
Core cross-section | 0.34 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | CJ4-12GK-N... | |
Effective internal capacitance | max. 60 nF , a cable length of 10 m is considered. | |
Effective internal inductance | negligibly small A cable length of 10 m is considered. | |
Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | CJ4-12GK-N... | |
Effective internal capacitance | max. 60 nF , a cable length of 10 m is considered. | |
Effective internal inductance | negligibly small A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | CJ4-12GK-N... | |
Effective internal capacitance | max. 60 nF , a cable length of 10 m is considered. | |
Effective internal inductance | negligibly small A cable length of 10 m is considered. | |
General information | ||
Supplementary information | Note! When making the electrical connection, ensure that the sensor cable is protected against mechanical stress! | |
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |