Mounting bracket SL-V96H Keyence
Mounting bracket SL-V96H Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

SL-V96H Keyence Mounting bracket

Manufacturer

Keyence

Country

Japan

Name

SL-V96H

Type

Mounting bracket

Description

Sicherheitslichtvorhang, Handschutz Schutzbereich 1945mm Japan 85371098990

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications SL-V96H

If you are inspecting Keyence SL-V96H , get in touch with FAMAGA, the world's main producer of industrialized equipment. Our company has lasted for more than ten years - these are ages of experience, which are outlined in the quality of merchandises and individual attention to each purchaser. We admire everyone, who conspired with us - thus, our regular customers obtain the most attractive purchase forms and discounts on the industrial equipment market. Now, there are more than 4000 such clients, and we constantly form new agreements. More than 750 affairs are settled per day, because FAMAGA delivers all over the earth . A advanced logistics link and a partnership network let us to send our products anywhere in the world promptly without compromising product quality.

A particular source of honor for FAMAGA is its employees, each of whom contributes to common cause. We propose into our team only experts, who already have experience in the range of industrial equipment.

All items from FAMAGA are verified - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been provided, and this number is growing every day. We are glad that purchasers choose FAMAGA again and again, and we are happy to make more exceptional and technologically developed industrial equipment so as to stay on the top.

To get some advice or book, get in touch with us or write a message to the online chat on our official website. You can also dispatch a list of the needful equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features SL-V96H

Main Unit, General-purpose Type, 96 Optical Axes
Model SL-V96H
Detection capability o25 mm
Beam axis spacing/Lens diameter 20 mm/o5 mm
Effective aperture angle Max. ±2.5 ° (When operating distance is 3 m or more)
Working distance 0.1 m to 9.0 m (detection height of 1,260 mm or l ess) 0.1 m to 7.0 m (detection height of 1,400 mm or more)
Response time (ms) ON>OFF 19.1*1
OFF>ON 59.1*1
Light source Infrared LED (850 nm)
Operation mode Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)
OSSD output Output 2 outputs each for PNP and NPN. Can be changed by using the connector cable.
Max. l oad current 500 mA*2
Residual vol tage (during ON) Max. 2.5 V (with a cable length of 7 m)
Leakage current Max. 100 µA*3
Max. capacitive load 2.2 µF (with a load resistance of 100 ?)
Load wiring resistance Max. 2.5 ?*4
Non safety-rel atedoutput AUX Output with automatic PNP/NPN switching function, 50 mA max.
Interlock-reset-ready output
Alarm output
Clear/blocked output
State information output 1, 2
Muting lamp output Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected
Input EDM input Short-circuit current 10 mA
Wait input Short-circuit current 2.5 mA
Reset input
Muting input 1, 2
Override input
Protection circuit Reverse current protection, short-circuit protection for each output, surge protection for each output
Approved standards EMC EMS IEC61496-1, EN61496-1, UL61496-1
EMI EN55011 Class A, FCC Part15B Class A
Safety IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD) IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe) UL508 UL1998
Rating Power voltage 24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less
Current consumption (mA) When the Centre indicator is ON Transmitter 154*6
Receiver 104*6
When the Centre indicator is OFF Transmitter 140*6
Receiver 83*6
Environmental resistance Enclosure rating IP65 (IEC60529)
Overvoltage category II
Ambient light Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.
Operating ambient temperature -10 to +55 °C (No freezing)
Storage temperature -25 to +60 °C (No freezing)
Operating relative humidity 15 to 85 % RH (No condensation)
Storage relative humidity 15 to 95 % RH
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Main unit case Aluminium
Upper case/lower case Zinc die-cast
Front cover Polycarbonate, SUS304
Weight Transmitter 1,260 g
Receiver 1,295 g
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of theresponse times of al l the individual SL-V units, but the response time (OFF to ON) is the sameas that of a singl e SL-V unit. e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), andSL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms. *2 When used under ambient temperature between 45 to 55 °C, the maximum should not exceed 300 mA. *3 Applies to situations when power is either off or disconnected. *4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 ? or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 ? or less. *5 When used under ambient temperature between 45 to 55 °C, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA). *6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.) In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state. In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.