IFM PN7093
  IFM PN7093

We are not the manufacturer, authorised distributor or authorised representative of the IFM brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

PN7093 IFM

Manufacturer

IFM

Country

Germany

Part number

PN7093

Description

Pressure sensor with display

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications PN7093

Two switching outputs, one of them with IO-Link communication interface. Red/green display for clear identification of the acceptable range. The process connection can be rotated for optimum alignment. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments.

Features PN7093

Application
Measuring elementCeramic capacitive pressure cell
ApplicationFor general industrial applications
MediaLiquid or gaseous media
Conditionally suitable forApplication in gaseous media pressure limited to 25 bar.
Measured medium temperature [°C]-25…80
Pressure strength
150 bar2175 psi15 MPa
Min. burst pressure
350 bar5075 psi35 MPa
Pressure TypeRelative Pressure
Electronic Data
Operating voltage [V]18…30 DC, (according to EN 50178 SELV/PELV)
Current consumption [mA]<35
Min. insulation resistance [M?]100, (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]<0, 3
Built-in watchdogyes
Inputs/outputs
Number of inputs and outputsNumber of digital outputs: 2
Outputs
Total number of outputs2
Output signalSwitching signal, IO-Link, (configurable)
Electrical versionPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed, (parameterizable)
Max. voltage drop DC switching output [V]2.5
DC switching output load current DC [mA]150, (200 (…60 °C) 250 (…40 °C))
DC switching frequency [Hz]<170
Short-circuit protectionyes
Short-circuit protection typeclocked td>
Overcurrent protectionyes
Measuring/setting range
Measuring range
0…25 bar0…363 psi 0…2.5 MPa
Switching point SP tbody>
0.2…25 bar4…362 psi0.02…2.5 MPa
Reset point rP
0.1…24.9 bar 2…360 psi0.01…2.49 MPa
Increments
0.1 bar2 psi0, 01 MPa
Accuracy/UncertaintySwitch Point Accuracy [% of Range]<± 0.5Repeatability [% of range]<± 0.1, (for temperature changes <10 K)Deviation of specification [% of range]<± 0.25 (BFSL) / <± 0.5 (LS), (BFSL = best fit straight line, LS = Limit value setting)Hysteresis deviation [% of span]<± 0.25 Long-term stability [% of span]<± 0.05, (over 6 months)Zero point temperature coefficient [% of span / 10 K ]0.2, (-25…80 °C)Temperature coefficient range [% of measuring range / 10 K]0.2, (-25…80 °C)Response timeResponse time [ms]<3Programmable delay time dS, dr [s]0…50Software / ProgrammingParameter selectionHysteresis /window, normally open/normally closed, switching logic, on/off delay, Damping, DisplayInterfaces Communication interfaceIO-LinkTransmission methodCOM2 (38.4 kBaud) IO-Link test1.1SDCI standardIEC 61131-9IO-Link device ID402 d / 00 01 92 hProfiles Smart Sensor: Process Data Variable, Device Identification, Device DiagnosisSIO Modeyes Desired port typeAAnalog operating data1Binary operating data2Min. cycle time [ms]2.3Operating conditionsAmbient temperature [°C]-25…80Storage temperature [°C]-40… 100Degree of protectionIP 65, IP 67Tests / approvals EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10…2000 Hz)
MTTF [years]224.01UL Certification
UL Registration Number J001
Y pressure equipment directiveGood engineering practice, can be used for fluid group 2, fluid group 1 on requestMechanical data Weight [g]233.5Materialstainless steel steel (1.4404 / 316L), PBT+PC-GF30, PBT-GF20, PC mediumstainless steel steel (1.4404 / 316L), ceramic, FKMMin. pressure cycles100 millionTightening torque [Nm]25…35, (recommended tightening torque, V depending on lubrication, sealing and pressure rating)Process connectionG 1/4 female threadDisplays / ControlsDisplay
Display3 x LED, green (bar, psi, MPa)
Output status2 x LED, yellow
Measured valuesalphanumeric display, red/green 4-digit
NotesPacking quantity1 pieceElectrical connectionConnectionConnector: 1 x M12, Contacts: gold-plated