Position indicator tico 772 Hengstler
Position indicator tico 772 Hengstler

We are not the manufacturer, authorised distributor or authorised representative of the Hengstler brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

tico 772 Hengstler Position indicator

Manufacturer

Hengstler

Country

USA

Name

tico 772

Type

Position indicator

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications tico 772

If you are seeking Hengstler tico 772 , make contact with FAMAGA, the world's foremost company of mechanized equipment. Our company has operated for more than ten years - these are cycles of experience, which are described in the quality of goods and private attention to each orderer. We praise everyone, who engaged with us - thus, our regular consumers pick up the most desirable purchase forms and discounts on the machine made streamlined equipment market. At this time, there are more than 3500 such consumers, and we constantly make new agreements. More than 700 proceedings are resolved per day, because FAMAGA delivers all over the globe . A well-built logistics network and a partnership network let us to dispatch our units anywhere in the globe promptly without disreputing product quality.

A particular source of dignity for FAMAGA is its team members, each of whom contributes to our work. We request into our team only experts, who already have experience in the range of factory-made equipment.

All outcomes from FAMAGA are verified - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been supplied, and this bulk is ascending every day. We are pleased that purchasers choose FAMAGA again and again, and we are happy to make more exceptional and technologically modern industrial equipment so as stay in control.

To get some advice or book, contact us or write a message to the online chat on our official website. You can also dispatch a list of the desirable equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.

Features tico 772

The members of this product family are really multitalented, feature up to three presets and can be connected up using plug-and-play connectors. They allow very high counting frequencies of up to 60 kilohertz and are universally suitable for use as pulse-counters, tachometers, timers, shift or batch counters. The large multi-coloured 6-digit display is backlit and easy to read. The flexibility of the programming levels offered by this multifunctional counter allows it to be used as a tachometer and, if required, with many programmable functions. tico 772 Tachometer
  • Very simple operation
  • Four different backlighting colours
  • Large, easily read display
  • Counting frequency up to 60 kHz
  • Three presets
  • Prescaler 0.0001 - 99.9999
Product Familytico 772
FunctionTachometer
TechnologyElectronic
Digits6-digit
Display
  • 6-digit
  • 2-line
  • count reading/presets
  • leading zero suppression
  • decimal point (up to 4 places)
Preset3 presets
Digit Height [mm]
  • 1. Line 9.3 mm (0.4 in)
  • 2. Line 7.2 mm (0.3 in)
Display Variant
  • reflective LCD
  • transflective positive LCD, black digits, backlit
  • transmissive negative LCD, white digits, red or green backlit, background black
View Angle12:00
Relay1 or 1 relays
Voltage
  • 12-30 VDC
  • 24-240 VAC
Reset
  • manual reset
  • electrical reset
  • automatic reset
Signal Times0.01 s to 599.99 s or bistable, programmable, tolerance + 10 ms, active on/off
Current Consumption [mA]
  • < 200 mA at 12-30 VDC reflective
  • < 250 mA at 12-30 VDC with backlight
  • <250 mA at 24 VAC
  • <50 mA at 115, 230 VAC
  • <80 mA at 100-240 VAC switching power supply
Power Consumption< 5 W?<8 W
Cable Cross-Section1...1.5 mm? (0.0015...0.0023 in?) with multicore cable end
Input Resistanceapprox. 10 kOhm
Pulse Length min.17 ms (30 Hz), 8 µs (60 kHz)
Supply Voltage
  • 12-30 VDC
  • 24, 115, 230 VAC
  • 100-240 VAC
Count Frequency [Hz]
  • max. 60 kHz (TTL 20 kHz): Single-channel counting and directional input
  • max. 60 kHz (TTL 20 kHz): differential or totalizing operation
  • channel (A+B together)
  • max. 30 kHz (TTL 20 kHz): phase discriminator 1- or 2-fold evaluation
  • max. 15 kHz (TTL 15 kHz): phase discriminator 4-fold evaluation
  • attenuated 30 Hz
  • For further details, see graphic and manual.
Overload Protection
  • ext. backup
  • DC: 0.16 AT (IEC 127), DC: 0.2 AT (UL 198)
  • 24 VAC: 315 mAT
  • 115 VAC: 63 mAT
  • 230 VAC: 32 mAT
  • 100-240 VAC 630 mAT
Overload Protection Relay Output
  • ext. backup 230 V
  • 2.5 A mT
Sensor Supply
  • transformer power supply: 12-24 VDC (load-dependent)
  • max. 50 mA
  • switch power supply24 VDC -5%
  • max. 115 mA, max. capacitative load 470 µF
Storage of ValuesNVM> 10 years
Electrical Connectionpluggable screw terminals / connecting clamps
Amplitude Threshold
  • 8 V or 4 V at TTL levels
  • amplitude max. 40 VDC
Active Edgeprogrammable, positive with PNP input, negative with NPN input
Pulse Shapeany square wave (1:1 for max. frequency)
Prescaler0.0001 - 99.9999
Set Functionset to VW 0 (independent of resets)
Display and Preset Range- 999 999 to + 999 999
Alarm Signal
  • display blinks
  • when presets 0,1 or 2 are active
Relay (Preset 1 and 2)
  • Varistor max. 250 VAC / 30 VDC / 5 A
  • Varistor min. 5 VAC / 5 VDC / 10 mA
  • Delay < 10 ms
Transistor output (Preset 1 + 2)
  • DC supply: PNP output 12 - 30 VDC, max. 50 mA
  • transformer performance (24, 115, 230 VAC): PNP output 12 - 24 VDC, max. 30 mA
  • switch power supply 100-240 VAC: PNP output 24 VDC, max. 50 mA
Application Output
  • DC supply: PNP output 12 - 30 VDC, max. 20 mA
  • transformer performance (24, 115, 230 VAC): PNP output 12 - 24 VDC, max. 20 mA
  • switch power supply 100-240 VAC: PNP output 24 VDC, max. 20 mA
Attention
  • Only for transformers (24, 115, m230 VAC:
  • The energy load on the outputs (sensors 12-24 VDC, out1, out2, Appl.-Outp.) may not be more than 65 mA total.
Counter Mode Input A,B
  • Single channel add or sub, directional input,
  • differential operation add / sub, totalizing operation add / add,
  • phase discriminator 1-, 2- or 4-fold evaluation
Preselect Modes
  • absolute or trailing preset
  • range signal/value limit (Sign. 1 < VW1
  • Sign. 2> VW2)
Application Input/Output (Counter)
  • Output: prescaler-out
  • preset 0-out
  • direction-out
  • input: additional counter input add / sub
  • reset
  • set
  • gate
  • keylock
  • hold
  • teach in
Modebatch counter with preset or 2. totalizing counter with preset
Count Mode
  • differential operation add/sub
  • totalizing operation add/add
Product Familytico 772
FunctionTachometer
TechnologyElectronic
Digits6-digit
Display
  • 6-digit
  • 2-line
  • count reading/presets
  • leading zero suppression
  • decimal point (up to 4 places)
Preset3 presets
Digit Height [mm]
  • 1. Line 9.3 mm (0.4 in)
  • 2. Line 7.2 mm (0.3 in)
Display Variant
  • reflective LCD
  • transflective positive LCD, black digits, backlit
  • transmissive negative LCD, white digits, red or green backlit, background black
View Angle12:00
Relay1 or 1 relays
Voltage
  • 12-30 VDC
  • 24-240 VAC
Reset
  • manual reset
  • electrical reset
  • automatic reset
Signal Times0.01 s to 599.99 s or bistable, programmable, tolerance + 10 ms, active on/off
Current Consumption [mA]
  • < 200 mA at 12-30 VDC reflective
  • < 250 mA at 12-30 VDC with backlight
  • <250 mA at 24 VAC
  • <50 mA at 115, 230 VAC
  • <80 mA at 100-240 VAC switching power supply
Power Consumption< 5 W?<8 W
Cable Cross-Section1...1.5 mm? (0.0015...0.0023 in?) with multicore cable end
Input Resistanceapprox. 10 kOhm
Pulse Length min.17 ms (30 Hz), 8 µs (60 kHz)
Supply Voltage
  • 12-30 VDC
  • 24, 115, 230 VAC
  • 100-240 VAC
Count Frequency [Hz]
  • max. 60 kHz (TTL 20 kHz): Single-channel counting and directional input
  • max. 60 kHz (TTL 20 kHz): differential or totalizing operation
  • channel (A+B together)
  • max. 30 kHz (TTL 20 kHz): phase discriminator 1- or 2-fold evaluation
  • max. 15 kHz (TTL 15 kHz): phase discriminator 4-fold evaluation
  • attenuated 30 Hz
  • For further details, see graphic and manual.
Overload Protection
  • ext. backup
  • DC: 0.16 AT (IEC 127), DC: 0.2 AT (UL 198)
  • 24 VAC: 315 mAT
  • 115 VAC: 63 mAT
  • 230 VAC: 32 mAT
  • 100-240 VAC 630 mAT
Overload Protection Relay Output
  • ext. backup 230 V
  • 2.5 A mT
Sensor Supply
  • transformer power supply: 12-24 VDC (load-dependent)
  • max. 50 mA
  • switch power supply24 VDC -5%
  • max. 115 mA, max. capacitative load 470 µF
Storage of ValuesNVM> 10 years
Electrical Connectionpluggable screw terminals / connecting clamps
Amplitude Threshold
  • 8 V or 4 V at TTL levels
  • amplitude max. 40 VDC
Active Edgeprogrammable, positive with PNP input, negative with NPN input
Pulse Shapeany square wave (1:1 for max. frequency)
Prescaler0.0001 - 99.9999
Set Functionset to VW 0 (independent of resets)
Display and Preset Range- 999 999 to + 999 999
Alarm Signal
  • display blinks
  • when presets 0,1 or 2 are active
Relay (Preset 1 and 2)
  • Varistor max. 250 VAC / 30 VDC / 5 A
  • Varistor min. 5 VAC / 5 VDC / 10 mA
  • Delay < 10 ms
Transistor output (Preset 1 + 2)
  • DC supply: PNP output 12 - 30 VDC, max. 50 mA
  • transformer performance (24, 115, 230 VAC): PNP output 12 - 24 VDC, max. 30 mA
  • switch power supply 100-240 VAC: PNP output 24 VDC, max. 50 mA
Application Output
  • DC supply: PNP output 12 - 30 VDC, max. 20 mA
  • transformer performance (24, 115, 230 VAC): PNP output 12 - 24 VDC, max. 20 mA
  • switch power supply 100-240 VAC: PNP output 24 VDC, max. 20 mA
Attention
  • Only for transformers (24, 115, m230 VAC:
  • The energy load on the outputs (sensors 12-24 VDC, out1, out2, Appl.-Outp.) may not be more than 65 mA total.
Counter Mode Input A,B
  • Single channel add or sub, directional input,
  • differential operation add / sub, totalizing operation add / add,
  • phase discriminator 1-, 2- or 4-fold evaluation
Preselect Modes
  • absolute or trailing preset
  • range signal/value limit (Sign. 1 < VW1
  • Sign. 2> VW2)
Application Input/Output (Counter)
  • Output: prescaler-out
  • preset 0-out
  • direction-out
  • input: additional counter input add / sub
  • reset
  • set
  • gate
  • keylock
  • hold
  • teach in
Modebatch counter with preset or 2. totalizing counter with preset
Count Mode
  • differential operation add/sub
  • totalizing operation add/add