CET3-AP-CRA-AH-50X-SI-C2290-121367 Euchner 121367
 CET3-AP-CRA-AH-50X-SI-C2290-121367 Euchner 121367

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

CET3-AP-CRA-AH-50X-SI-C2290-121367 121367 Euchner

Manufacturer

Euchner

Country

Germany

Name

CET3-AP-CRA-AH-50X-SI-C2290-121367

Part number

121367

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CET3-AP-CRA-AH-50X-SI-C2290-121367 121367

If you are questing Euchner CET3-AP-CRA-AH-50X-SI-C2290-121367 121367, call FAMAGA, the world's the best retailer of machine made equipment. Our company has progressed for more than ten years - these are cycles of experience, which are symbolized in the quality of products and private attention to each purchaser. We understand everyone, who joined with us - so, our regular customers bring in the most acceptable purchase conditions and discounts on the manufacturing equipment market. Nowadays, there are more than 4000 such consumers, and we constantly form new agreements. More than 650 agreements are achieved per day, because FAMAGA works all over the world . A well-built logistics connection and a partnership network allow us to deliver our goods anywhere in the world with no delay without compromising product quality.

A special source of pride for FAMAGA is its staff members, each of whom contributes to our work. We request into our team only experts, who already have experience in the field of machine made streamlined equipment.

All goods from FAMAGA are guaranteed - we are responsible for the result of our work. At this moment, more than 10 million units of products have been shipped, and this quantity is rising every day. We are proud that buyers choose FAMAGA again and again, and we strive to make more advanced and technologically advanced industrial equipment so as to stay on the top.

To consult or order, get in touch with us or write to the online chat on our site. You can also direct a list of the required equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features CET3-AP-CRA-AH-50X-SI-C2290-121367 121367

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • Indication of the door position by LED
  • Wire front release (bowden), 5 m
  • Approach direction A (default setting on delivery)
Approach direction Horizontal Can be adjusted in 90° steps Safety switchThe device may be operated only in conjunction with the actuator CET-A-.... Important: The actuator must be ordered separately. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Solenoid operating voltage
  • DC 24 V +10% -15%
Guard locking type
CET3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.
LED function display
LED StateStatus LED
LED DIADiagnostic LED
LED 1 rdilluminates when the solenoid is energized
LED 2 gnilluminates when door is closed
Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. The category is dependent on the installation position of the safety switch: Wire front release (bowden)The wire front release permits remote unlocking of the guard locking via a pull wire. Flexible routing of the pull wire permits release of the guard locking in inaccessible installation situations. Important: The wire front release (bowden) is not a safety function.
Housing material
Slide Stainless steel
Safety switch housing Die-cast aluminum
Weight
Net 1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mechanical life 1 x 106
Installation orientation Any
Degree of freedom
Z ±4 mm
Y ±5 mm
X ±5 mm
Ready delay 1 s
Switching frequency max.0,5 Hz
Connection 2 plug connectors M12, 5-pin
Approach speed 20 m/min
Guard locking principle Closed-circuit current principle
Locking force Fmax 6500 N
Locking force FZh 5000 N
Electrical connection ratings
Operating voltage DC
UB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
LED 24 V DC -15% ... 10%
Current consumption
IB 80 mA
ICM 480 mA
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Solenoid operating voltage DC
UCM 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Fusing
External (operating voltage UB) 0,25 ... 8 A
External (solenoid operating voltage UCM) 0,5 ... 8 A
Power consumption
Solenoid max.12 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Solenoid duty cycle 100 %
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable 30V DC, 2A
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs OA/OB
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output OA / OB 1 ... 200 mA
Output voltage
High U(OA) / U(OB) UB-1,5V ... UB V DC
Low U(OA) / U(OB) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Risk time according to EN 60947-5-3
Single device max.400 ms
Switch-on time 400 ms
Discrepancy time
Both safety outputs max.10 ms
Work area
Repeat accuracy R 10 %
Other
C number
C2290 With wire front release (bowden) mounted
For the approval according to UL the following applies
Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category
Head downward or horizontal 4
Head upward 3
Performance Level PL e
PFHD
Head upward 4.29 x 10-8
Head downward or horizontal 3.1 x 10-9
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Mission time 20 y