Manufacturer
Euchner
Country
Germany
Name
MGB-L2H-ARA-R-105786
Part number
105786
Description
Safety Lock MGB-L2H-AR-R-105786
Stock availability:
On request
If you are seeking Euchner MGB-L2H-ARA-R-105786 105786, get in touch with FAMAGA, the world's key provider of mechanized equipment. Our company has lasted for more than ten years - these are cycles of experience, which are depicted in the quality of outputs and private attention to each consumer. We respect everyone, who worked with us - hence, our regular consumers obtain the most flexible purchase terms and discounts on the manufacturing equipment market. Now, there are more than 4 thousand such purchasers, and we constantly form new agreements. More than 750 contracts are concluded per day, because FAMAGA works all over the globe Germany, United Kingdom, South Sudan, Haiti, Kuwait, Burkina Faso, Ireland, Fiji, Mongolia, Belgium, Liechtenstein, Uganda, Poland, Eritrea, Mauritius, Mexico, Japan, Grenada, United States, Hungary, Monaco, Oman, Georgia, Syria, Uzbekistan, Djibouti, Indonesia, Egypt, Yemen, Libya, Mozambique, Philippines, Macedonia, Afghanistan, Armenia, Cyprus, Vietnam, Pakistan, Iran, Estonia, Equatorial Guinea, Comoros, Botswana, China, Andorra. A well-developed logistics chains and a partnership network help us to ship our units anywhere in the world quickly without disreputing product quality.
A special source of repute for FAMAGA is its employees, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the range of industrial equipment.
All items from FAMAGA are verified - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been shipped, and this quantity is ascending every day. We are happy that purchasers choose FAMAGA again and again, and we strive to make more progressive and technologically innovative industrial equipment so as to stay on the top.
To request or place an order, get in touch with us or send a message to the online chat on our site. You can also dispatch a list of the required equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Any |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Mission time | 20 y |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Product version number | V3.0.0 |