MGB-L2HC-ARA-R-112531 112531 Euchner

Manufacturer

Euchner

Country

Germany

Name

MGB-L2HC-ARA-R-112531

Part number

112531

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications MGB-L2HC-ARA-R-112531 112531

If you are looking for Euchner MGB-L2HC-ARA-R-112531 112531, communicate with FAMAGA, the world's main retailer of factory-made equipment. Our company has worked for more than ten years - these are years of experience, which are represented in the quality of items and personalseparate attention to each consumer. We cherish everyone, who collaborated with us - hence, our regular purchasers bring in the most favorable purchase conditions and discounts on the manufacturing equipment market. At present, there are more than 4 thousand such customers, and we constantly make new agreements. More than 750 purchases are terminated per day, because FAMAGA supplies all over the planet . A well-developed logistics bond and a partnership network assist us to send our elements anywhere in the planet with no delay without disreputing product quality.

A special source of honor for FAMAGA is its staff members, each of whom contributes to common cause. We accept into our team only specialists, who already have experience in the direction of machine made streamlined equipment.

All items from FAMAGA are affirmed - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been provided, and this quantity is rising every day. We are happy that buyers choose FAMAGA again and again, and we are happy to make more progressive and technologically advanced industrial equipment so as keep on top of it.

To request or make a request, call us by phone or write to the online chat on our site. You can also forward a list of the necessary equipment to the email of organization - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features MGB-L2HC-ARA-R-112531 112531

  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With control module MGB-C
  • Emergency stop according to ISO 13850
  • 3 pushbuttons (illuminated, wh, wh, bu)
  • 2 indicators (illuminated, gn, rd)
  • Incl. adhesive labels
  • With plug connector RC26
  • Unicode
Guard locking type
MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked).
Door hinge A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicator The LED indicator indicates all important system and status information. Monitoring outputs
ODON when the door is closed
OTBolt tongue inserted in the evaluation module
OLGuard locking solenoid in locked position
OIDiagnostics, there is a fault
Emergency stop device
S12 positively driven NC contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated
Pushbutton
S101 NO contact, white, illuminated
S111 NO contact, white, illuminated
S151 NO contact, blue, illuminated
Indicators
H12LED, green
H14LED, red
Adhesive labels Devices with adhesive labels have pre-formed recesses. The adhesive labels enclosed (standard size 12.5 x 27 mm) can be affixed in these recesses. Dimension drawing Dimension drawing Plug connector RC26 MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing single wiring (AP) to series wiring (AR) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingDimension drawingPlug connector RC26 Technical data Locking module MGB-L2C-ARA-R-112529 (Order no. 112529) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 1,4 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP65
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN right
Switching frequency 0,25 Hz
Connection Plug connector RC26
Guard locking principle Open-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1,5 kV
Degree of contamination (external, according to EN 60947-1) 3
Safety class III
Discrepancy time
Between FO1A and FO1B max.10 ms
Risk time according to EN 60947-5-3 max.350 ms
Transponder coding Unicode
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... 10%
Current consumption
IUB max.80 mA
Power supply UA
Operating voltage DC
UA 24 V DC -15% ... 10%
Current consumption
IUA max.375 mA
Safety outputs FO1A, FO1B
Test pulses max.1 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-2V ... UB V DC
Output current
Per safety output FO1A / FO1B 1 ... 200 mA
Monitoring outputs OD, OT, OL, OI
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC
Output current max.50 mA
Controls and indicators
Switching voltage UA V
Switching current 1 ... 10 mA
Breaking capacity max.0,25 W
Power supply LED 24 V DC
Emergency stop
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
Breaking capacity max.0,25 W
Power supply LED 24 V DC
Solenoid control input IMP1, IMP2, IMM
Test pulses max.5 ms
Test-pulse interval min.100 ms
Other
Product version number V3.0.3
Slide-in label 5 pc. without marking
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Emergency stop
B10D
Emergency stop 0,065 x 106
Mission time 20 y
Handle module MGB-H-AA1A3-R-111157 (Order no. 111157) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 1,00 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP65
Installation orientation Door hinge DIN right
Other
Additional feature With automatic lockout mechanism
Product version number V3.0.0
Components 112529 Locking module MGB-L2C-ARA-R-112529
  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With control module MGB-C
  • Emergency stop according to ISO 13850
  • 3 pushbuttons (illuminated, wh, wh, bu)
  • 2 indicators (illuminated, gn, rd)
  • Incl. adhesive labels
  • With plug connector RC26
  • Unicode
111157 Handle module MGB-H-AA1A3-R-111157
  • Intelligent bolt tongue
  • Fold-out lockout mechanism
  • Second automatically extending lockout mechanism
  • Door handle