Manufacturer
Euchner
Country
Germany
Name
CET3-AR-CRA-CH-50X-SG-110906
Part number
110906
Description
Security lock Sicherheitsschloss CET3-AR-CRA-CH-50X-SG
Stock availability:
On request
If you are questing Euchner CET3-AR-CRA-CH-50X-SG-110906 110906, connect FAMAGA, the world's principle retailer of industrialized equipment. Our company has functioned for more than ten years - these are ages of experience, which are represented in the quality of products and personalseparate attention to each orderer. We cherish everyone, who liased with us - therefore, our regular purchasers bring in the most helpful purchase terms and discounts on the manufacturing equipment market. Nowadays, there are more than 4500 such customers, and we constantly arrange new agreements. More than 750 agreements are achieved per day, because FAMAGA operates all over the earth Germany, United Kingdom, Yemen, New Zealand, Central African Republic, Mexico, Peru, Tanzania, Dominica, Portugal, Israel, Niger, Panama, Guatemala, Jordan, Guyana, Andorra, Canada, Slovakia, Iceland, Seychelles, Saudi Arabia, Turkmenistan, Iran, Malaysia, Ghana, Montenegro, North Korea, Uzbekistan, Jamaica, Brazil, Australia, South Korea, Mongolia, Antigua and Barbuda, Czech Republic, Zimbabwe, Belize, Austria, Uganda, Belarus, Rwanda, East Timor, Mali, Georgia. A well-developed logistics link and a partnership network guide us to ship our goods anywhere in the earth on-time without damaging product quality.
A particular source of pride for FAMAGA is its employees, each of whom contributes to common cause. We accept into our team only experts, who already have experience in the field of machine made streamlined equipment.
All merchandises from FAMAGA are guaranteed - we are responsible for the outcome of our work. At this moment, more than 10 million units of products have been provided, and this quantity is growing every day. We are glad that clients choose FAMAGA again and again, and we strive to make more advanced and technologically advanced industrial equipment so as keep on top of it.
To consult or place an order, get in touch with us or write a message to the online chat on our site. You can also send a list of the needful equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
Housing material | |
Safety switch housing | Die-cast aluminum |
Slide | Stainless steel |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
ICM | 480 mA |
IB | 80 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |