We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Euchner MGB-L2-ARA-BA1A1-M-109945 109945, catch up with FAMAGA, the world's foremost distributor of streamlined equipment. Our company has functioned for more than ten years - these are cycles of experience, which are depicted in the quality of items and special attention to each purchaser. We esteem everyone, who engaged with us - so, our regular buyers procure the most beneficial purchase terms and discounts on the factory-made equipment market. At present, there are more than 4 thousand such consumers, and we constantly sign new agreements. More than 600 purchases are terminated per day, because FAMAGA works all over the planet Germany, United Kingdom, Gabon, Monaco, South Sudan, Malawi, Eritrea, Equatorial Guinea, Yemen, Philippines, Bhutan, Malaysia, Burma, Bulgaria, Oman, Poland, Brazil, Madagascar, Fiji, Mongolia, Cameroon, Belize, The Bahamas, East Timor, Pakistan, Bolivia, Kazakhstan, Denmark, Afghanistan, Ireland, Libya, Russia, Luxembourg, Croatia, Mauritius, Mozambique, Panama, Egypt, Burkina Faso, Ukraine, Benin, Qatar, United Arab Emirates, Guatemala, The Gambia, Czech Republic. A well-elaborated logistics series and a partnership network assist us to ship our goods anywhere in the world quickly without discrediting product quality.
A specific source of dignity for FAMAGA is its staff members, each of whom contributes to common cause. We invite into our team only specialists, who already have experience in the sphere of industrial equipment.
All outputs from FAMAGA are assured - we are responsible for the result of our work. Now, more than 10 million units of products have been shipped, and this amount is rising every day. We are happy that clients choose FAMAGA again and again, and we are eager to make more developed and technologically innovative industrial equipment so as to stay on the top.
To get some advice or place an order, phone us or write to the online chat on our site. You can also direct a list of the required equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Mission time | 20 y |