We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are pursuing Euchner MGB-L2HB-PN-R-109856 109856, contact FAMAGA, the world's top distributor of industrialized equipment. Our company has progressed for more than ten years - these are years of experience, which are represented in the quality of spare parts and personalseparate attention to each user. We appreciate everyone, who collaborated with us - thus, our regular customers accept the most favorable purchase forms and discounts on the machine made streamlined equipment market. At present, there are more than 4500 such consumers, and we constantly sign new agreements. More than 700 purchases are terminated per day, because FAMAGA supplies all over the world Germany, United Kingdom, Côte d\'Ivoire, Uzbekistan, Belize, Netherlands, Chad, Haiti, Thailand, North Korea, Romania, Andorra, Oman, Yemen, Grenada, Czech Republic, Egypt, Bulgaria, Ecuador, Albania, Croatia, Angola, Turkmenistan, Equatorial Guinea, Namibia, Macedonia, Madagascar, United Arab Emirates, Ghana, Niger, Mexico, Burundi, Mongolia, Tonga, Algeria, Libya, Tanzania, Chile, Rwanda, Djibouti, Moldova, Denmark, Norway, Slovakia, Tunisia, Comoros. A well-elaborated logistics series and a partnership network assist us to dispatch our goods anywhere in the earth promptly without compromising product quality.
A specific source of dignity for FAMAGA is its staff members, each of whom contributes to our work. We accept into our team only specialists, who already have experience in the field of machine made streamlined equipment.
All outputs from FAMAGA are guaranteed - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been provided, and this bulk is growing every day. We are glad that customers choose FAMAGA again and again, and we are eager to make more exceptional and technologically advanced industrial equipment so as keep on top of it.
To get some advice or make a request, contact us or write to the online chat on our site. You can also send a list of the needful equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Additional feature | With mounting plate |
Product version number | V3.0.0 |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 3,1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP54 |
Resilience to vibration | In accordance with EN 60947-5-3 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Reaction time | |
Emergency stop / machine stop | max.250 ms Switch-off time |
Door position | max.550 ms Switch-off time |
Bolt position | max.550 ms Switch-off time |
Guard locking | max.550 ms Switch-off time |
Switching frequency | 0,25 Hz |
Connection | |
Push-pull power | |
Push-pull power | |
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 |
Push-pull RJ45 | |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1, X2 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Safety class | III |
Transponder coding | Multicode |
Power supply X1 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Fusing | |
external | min.1 A Slow blow |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Assured switch-off distance Sar | max.65 mm |
Data interface | |
Data protocol | |
Bus protocol | Profinet (IEC 61158 type 10) |
Safety protocol | Profisafe (IEC 61784-3-3) |
Product version number | V3.30.10 |
Slide-in label | |
2 pcs. without marking | |
Anforderung | |
Quittieren | |
Acknowl. Start station | |
Access request | |
Load On start station |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.07 x 10-8 |
Diagnostic Coverage (DC) | 99 |
Emergency stop | |
B10D | |
Emergency stop | 0.1 x 106 |
Emergency-stop evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Mission time | 20 |