We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are seeking Euchner MGB-L1C-ARA-R-109798 109798, connect FAMAGA, the world's chief vendor of industrialized equipment. Our company has progressed for more than ten years - these are years of experience, which are outlined in the quality of outputs and special attention to each user. We understand everyone, who liased with us - hence, our regular buyers accept the most convenient purchase terms and discounts on the manufacturing equipment market. Now, there are more than 4 thousand such customers, and we constantly sign new agreements. More than 750 contracts are concluded per day, because FAMAGA works all over the world Germany, United Kingdom, South Sudan, Georgia, Uzbekistan, Guyana, Sri Lanka, Suriname, Panama, Liberia, Vietnam, Saudi Arabia, Australia, Japan, Afghanistan, Israel, Kuwait, The Gambia, Mali, Denmark, Cameroon, Russia, Tajikistan, Guatemala, Estonia, Turkey, Ukraine, Yemen, Burkina Faso, Montenegro, Jamaica, Samoa, United Arab Emirates, Fiji, Latvia, Togo, Poland, Comoros, Nigeria, Mauritania, Switzerland, Djibouti, South Korea, Malaysia, Ghana. A well-elaborated logistics connection and a partnership network help us to ship our goods anywhere in the planet immediately without discrediting product quality.
A particular source of pride for FAMAGA is its staff members, each of whom contributes to common cause. We invite into our team only experts, who already have experience in the field of manufacturing equipment.
All spare parts from FAMAGA are assured - we are responsible for the result of our work. At the moment, more than 10 million units of products have been delivered, and this quantity is rising every day. We are happy that customers choose FAMAGA again and again, and we are eager to make more progressive and technologically innovative industrial equipment so as to stay on the top.
To consult or order, get in touch with us or send a message to the online chat on our site. You can also send a list of the necessary equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts and 1 NO contact (e.g. monitoring contact), emergency stop with turn-to-reset, not illuminated |
S10 | 1 NO contact, white, illuminated |
S11 | 1 NO contact, white, illuminated |
S15 | 1 NO contact, blue, illuminated |
H12 | LED, green |
H14 | LED, red |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,4 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC26 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Belegungsschema | C2 |
Belegungsschema | L0 |
Position 10 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | white |
Schaltelement | 1NO |
Position 11 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | white |
Schaltelement | 1NO |
Position 12 | |
Ausfuhrung | Cover for indicators |
Einlegeschild | |
Extras | |
Farbe | Green |
Schaltelement | |
Position 13 | |
Ausfuhrung | Emergency stop |
Einlegeschild | Adhesive label D40mm |
Extras | With auxiliary contact |
Farbe | |
Schaltelement | 2 pos. driven NC + 1NO |
Position 14 | |
Ausfuhrung | Cover for indicators |
Einlegeschild | |
Extras | |
Farbe | Red |
Schaltelement | |
Position 15 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | Blue |
Schaltelement | 1NO |
Product version number | V3.0.3 |
Slide-in label | 5 pc. without marking |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |