We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Euchner MGB-L1H-APA-R-109772 109772, connect FAMAGA, the world's top provider of machine made equipment. Our company has lasted for more than ten years - these are ages of experience, which are symbolized in the quality of items and individual attention to each consumer. We understand everyone, who collaborated with us - so, our regular clients obtain the most convenient purchase conditions and discounts on the factory-made equipment market. Nowadays, there are more than 4500 such consumers, and we constantly make new agreements. More than 600 agreements are achieved per day, because FAMAGA supplies all over the world Germany, United Kingdom, Ecuador, Tunisia, Guyana, Turkmenistan, Lesotho, Uruguay, Eswatini, Monaco, Norway, Netherlands, Morocco, Liberia, Kazakhstan, South Korea, Iran, Antigua and Barbuda, Botswana, Panama, Philippines, Belize, Bosnia and Herzegovina, Niger, Nigeria, Swaziland, Togo, Turkey, Israel, Indonesia, Cameroon, Greece, Tanzania, Azerbaijan, Ghana, Macedonia, Kyrgyzstan, Paraguay, Luxembourg, Chile, Kenya, Kiribati, Rwanda, Tonga, Madagascar. A well-built logistics chains and a partnership network cheer us to send our items anywhere in the planet quickly without undermining product quality.
A special source of dignity for FAMAGA is its team members, each of whom contributes to common cause. We propose into our team only professionals, who already have experience in the field of manufacturing equipment.
All items from FAMAGA are ensured - we are responsible for the aftereffect of our work. At the moment, more than 10 million units of products have been delivered, and this amount is increasing every day. We are glad that consumers choose FAMAGA again and again, and we are happy to make more developed and technologically advanced industrial equipment so as keep on top of it.
To get some advice or order, phone us or write a message to the online chat on our site. You can also send a list of the necessary equipment to the email of firm - we will contact you ourselves with a made commercial proposal from FAMAGA.
MGB-L1... | The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OI | Diagnostics, there is a fault |
S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, illuminated |
S2 | 1 NO contact, white, illuminated |
S3 | 1 NO contact, white, illuminated |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Additional feature | With automatic lockout mechanism |
Product version number | V3.0.0 |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0,25 Hz |
Connection | Plug connector RC18 |
Guard locking principle | Closed-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Controls and indicators | |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Emergency stop | |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
Breaking capacity | max.0,25 W |
Power supply LED | 24 V DC |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Product version number | V3.0.3 |
Slide-in label | 2 pcs. without marking |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Control of the guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Emergency stop | |
B10D | |
Emergency stop | 0,065 x 106 |
Mission time | 20 y |