Proportional directional valve  Bosch Rexroth R901102112
Proportional directional valve  Bosch Rexroth R901102112

We are not the manufacturer, authorised distributor or authorised representative of the Bosch Rexroth brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

R901102112 Bosch Rexroth Proportional directional valve

Manufacturer

Bosch Rexroth

Country

Germany

Part number

R901102112

Category

Proportional directional valves

Type

Proportional directional valve

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications R901102112

Set-up: Valve with integrated sensors: The valve basically consists of:
  • Housing (1) and pressure sensor plate (12) with connection surface
  • Control spool (2) with compression springs (3 and 4) and spring plates (8 and 9)
  • Coils (5 and 6) and pole tubes (14 and 15) with central thread
  • Position transducer (7)
  • Integrated pressure sensors (10)
  • Integrated digital control electronics IAC-P (11)
Functional description
  • With de-energized solenoids (5 and 6), the control spool (2) is brought into the central position by compression springs (3 and 4) between the spring plates (8 and 9) (with V spool valve without spring plate). With V spool valves, the mechanical zero position does not correspond to the hydraulic one.
  • Depending on the valve type, the following functions result (some of them can be combined):
  • Flow control (Q)
  • Flow control (Q)
  • Pressure control in A and/or B (p)
  • Force control (p)
  • Substitutional control p/Q
  • The command value presetting can alternatively be specified via an analog interface (X1) or via the field bus interface (X2, X3).
  • The actual value signals are provided via an analog interface (X1) and can additionally be read out via the field bus (X2, X3).
  • The controller parameters are set via the field bus
  • Separate supply voltage for bus/controller and power part (output stage) for safety reasons
The digital integrated control electronics enables the following error detection:
  • Cable break pressure sensor (10)
  • Undervoltage
  • Cable break position transducer (7)
  • Communication error
  • Watchdog
  • Cable break command value inputs (only with current interface)
The following additional functions are available:
  • Ramp generator
  • Internal command value profile
  • Enable function analog / digital
  • Error output 24 V
PC program WIN-PED 6 To implement the project planning task and to parameterize the IFB-P valves, the user may use the WIN-PED commissioning software.
  • Parameterization
  • Diagnosis
  • Comfortable data management on a PC
System requirements
  • IBM PC or compatible system
  • Windows 2000 or Windows XP
  • RAM (recommendation: 256 MB)
  • 150 MB of available hard disk capacity
Notice
  • The "WIN-PED 6" PC program is not included in the scope of delivery. It is available for free download!
4WREQ 6 with integrated pressure sensors Set-up: Valve for external sensor: The valve basically consists of:
  • Housing (1) with connection surface
  • Control spool (2) with compression springs (3 and 4) and spring plates (8 and 9)
  • Coils (5 and 6) and pole tubes (14 and 15) with central thread
  • Position transducer (7)
  • Integrated digital control electronics IAC-P (11)
  • Port (X4) for an external pressure sensor (12)
Functional description
  • With de-energized solenoids (5 and 6), the control spool (2) is brought into the central position by compression springs (3 and 4) between the spring plates (8 and 9) (with V spool valve without spring plate). With V spool valves, the mechanical zero position does not correspond to the hydraulic one.
  • Functions:
  • Flow control (Q)
  • Pressure control (p)
  • Substitutional control p/Q
  • The command value presetting can alternatively be specified via an analog interface (X1) or via the field bus interface (X2, X3).
  • The actual value signals are provided via an analog interface (X1) and can additionally be read out via the field bus (X2, X3).
  • The controller parameters are set via the field bus
  • Separate supply voltage for bus/controller and power part (output stage) for safety reasons
The digital integrated control electronics enables the following error detection:
  • Cable break pressure sensor (depending on sensor interface)
  • Undervoltage
  • Cable break position transducer (7)
  • Communication error
  • Watchdog
  • Cable break command value inputs (only with current interface)
The following additional functions are available:
  • Ramp generator
  • Internal command value profile
  • Enable function analog / digital
  • Error output 24 V
PC program WIN-PED 6 To implement the project planning task and to parameterize the IFB-P valves, the user may use the WIN-PED commissioning software.
  • Parameterization
  • Diagnosis
  • Comfortable data management on a PC
System requirements
  • IBM PC or compatible system
  • Windows 2000 or Windows XP
  • RAM (recommendation: 256 MB)
  • 150 MB of available hard disk capacity
Notice
  • The "WIN-PED 6" PC program is not included in the scope of delivery. It is available for free download!
4WREQ 6 for external pressure sensor Important notice: The PG fitting (13) must not be opened. Mechanical adjustment of the adjustment nut located below is prohibited and damages the valve! Notice! Due to the design principle, internal leakage is inherent to the valves, which may increase over the life cycle. The tank line must not be allowed to run empty. With corresponding installation conditions, a preload valve must be installed.

Features R901102112

  • Size 6, 10
  • Component series 2X
  • Maximum operating pressure 315 bar
  • Maximum flow 180 l/min