Proportional pressure reducing valve 4WRZE 10 W8-50-7X/6EG24N9ETK31/F1M Bosch Rexroth R901144325
Proportional pressure reducing valve 4WRZE 10 W8-50-7X/6EG24N9ETK31/F1M Bosch Rexroth R901144325

We are not the manufacturer, authorised distributor or authorised representative of the Bosch Rexroth brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

4WRZE 10 W8-50-7X/6EG24N9ETK31/F1M R901144325 Bosch Rexroth Proportional pressure reducing valve

Manufacturer

Bosch Rexroth

Country

Germany

Name

4WRZE 10 W8-50-7X/6EG24N9ETK31/F1M

Part number

R901144325

Type

Proportional pressure reducing valve

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications 4WRZE 10 W8-50-7X/6EG24N9ETK31/F1M R901144325

Pilot-operated proportional directional valves type 4WRZ(E)… and 5WRZ(E).52… Valves of type 4WRZ(E)... are pilot-operated 4-directional valves that are actuated by means of proportional solenoids. Their function is to control the flow direction and size. Valves of type 5WRZ(E)... are equipped with an additional port "R" (only NG52). Set-up: The valve basically consists of: Pilot control valve (9) with proportional solenoids (5 and 6) Main valve (10) with main control spool (11) and centering spring (12) Function: With de-energized solenoids (5, 6), the main control spool (11) is held in the central position by means of the centering spring (12) The main control spool (11) is controlled by the pilot control valve (9); the main control spool is proportionally moved, e.g. by actuating solenoid "b" (6) → The control spool (2) is moved to the right, pilot oil enters the pressure chamber (13) via the pilot control valve (9) and deflects the main control spool (11) proportionally to the electric input signal → Connection from P to A and B to T via orifice-type cross-sections with progressive flow characteristics Pilot oil supply to the pilot control valve internally via port P or externally via port X Switching off the solenoid (6) → The control spool (2) and main control spool (11) are moved back into the central position Depending on the spool position, flow occurs from P to A and B to T or P to B and A to T (R) An optional manual override (14 and 15) can be used to move the control spool (2) without solenoid energization. Notice: Accidental activation of the manual override may lead to uncontrolled machine movements! Notice: Due to the design principle, internal leakage which may increase over the life cycle is inherent to the valves.

Features 4WRZE 10 W8-50-7X/6EG24N9ETK31/F1M R901144325

  • Size 10, 16, 25, 32, 52
  • Component series 7X
  • Maximum operating pressure 350 bar
  • Maximum flow 2800 l/min