Trip amplifier 2/208 Pepperl+Fuchs 542488
Trip amplifier 2/208 Pepperl+Fuchs 542488

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

2/208 542488 Pepperl+Fuchs Trip amplifier

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

2/208

Part number

542488

Type

Trip amplifier

Description

  • 1-channel
  • Input 0/4 mA ... 20 mA
  • 2 relay contact outputs
  • Simple operation via front buttons
  • Lead monitoring
  • Galvanic isolation between input, power supply and contact output
  • LCD display
  • Self-monitoring

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications 2/208 542488

The adjustable device is used to monitor trip values (min/max). The device is being operated via front push-buttons.

Features 2/208 542488

Product Description
Trip amplifier with 1-2 trip values
General specifications
Signal typeAnalog input
Supply
Connectiondz2+, dz4-, dz6 (PE)
Rated voltage20 ... 30 V DC 20 ... 26.4 V AC 48 ... 62 Hz
Power consumption1.5 W / 2 VA
Input
ConnectionInput I: d32+, z32-
Input resistance50 &Omega, (mA) 10 k&Omega, (V)
Current range0/4 ... 20 mA (0/1 ... 5 V)
Output
ConnectionOutput I: z10, d10, z12, d12, z14, d14 Output II: d20, z20, d18, z18, d16, z16
Relay
Switching voltage50 V
Switching current1.25 A AC/DC
Switching power60 VA / 30 W
Mechanical life20 Mio. cycles
Electrical life0.5 Mio. cycles
Response time> 20 ms (variable)
Indicators/settings
Display elementsLED 1: trip value 1 LED 2: trip value 2 LED 3: lights up if measured value falls below trip value 1 LED 4: lights up if measured value falls below trip value 2
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECThe device has been used for the same applications for several years. It therefore features an appropriate electromagnetic field immunity. The device must not be used in new plants.
Ambient conditions
Ambient temperature-10 ... 60 °C (14 ... 140 °F)
Storage temperature-25 ... 80 °C (-13 ... 176 °F)
Mechanical specifications
Mass300 g