Specifications NBB15-30GM50-E3-V1-3G-3D 225846

If you are seeking Pepperl+Fuchs NBB15-30GM50-E3-V1-3G-3D 225846, connect FAMAGA, the world's major producer of mechanized equipment. Our company has functioned for more than ten years - these are years of experience, which are depicted in the quality of spare parts and personalseparate attention to each orderer. We appreciate everyone, who joined with us - therefore, our regular buyers obtain the most acceptable purchase conditions and discounts on the industrial equipment market. Today, there are more than 3500 such customers, and we constantly make new agreements. More than 650 transactions are made per day, because FAMAGA operates all over the globe . A well-developed logistics network and a partnership network allow us to conduct our items anywhere in the globe as soon as possible without disreputing product quality.

A special source of good name for FAMAGA is its personnel, each of whom contributes to our work. We accept into our team only professionals, who already have experience in the field of industrial equipment.

All products from FAMAGA are assured - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been shipped, and this number is amounting every day. We are pleased that customers choose FAMAGA again and again, and we are happy to make more advanced and technologically developed industrial equipment so as not to lower the bar.

To ask a question or book, get in touch with us or write to the online chat on our official website. You can also send a list of the desirable equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features NBB15-30GM50-E3-V1-3G-3D 225846

General specifications
Switching functionNormally closed (NC)
Output typePNP
Rated operating distance15 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 12.15 mm
Reduction factor rAl 0.3
Reduction factor rCu 0.3
Reduction factor r304 0.75
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 200 Hz
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le, 3 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA typ. 0.1 µ,A at 25 °C
No-load supply current&le, 15 mA
Switching state indicatorMultihole-LED, yellow
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialbrass, nickel-plated
Sensing facePBT
Degree of protectionIP67
Equipment protection level Gc (nA)
CertificatePF 15CERT3754 X
CE marking[*PD-Z02586A*]
ATEX marking II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=30 V, IL=200 mA54 °C (129.2 °F)
at UBmax=30 V, IL=100 mA57 °C (134.6 °F)
at UBmax=30 V, IL=50 mA58 °C (136.4 °F)
Equipment protection level Dc (tc)
CE marking[*PD-Z02586A*]
ATEX marking II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=30 V, IL=200 mA54 °C (129.2 °F)
at UBmax=30 V, IL=100 mA57 °C (134.6 °F)
at UBmax=30 V, IL=50 mA58 °C (136.4 °F)
Equipment protection level Dc (tD)
GeneralThe apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to!
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=30 V, IL=200 mA54 °C (129.2 °F)
at UBmax=30 V, IL=100 mA57 °C (134.6 °F)
at UBmax=30 V, IL=50 mA58 °C (136.4 °F)
General information
Use in the hazardous areasee instruction manuals
Category3G, 3D