We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NBB15-30GM50-E3-V1-3G-3D
Part number
225846
Type
Inductive sensor
Description
Inductive sensor NBB15-30GM50-E3-V1-3G-3D
Stock availability:
On request
If you are seeking Pepperl+Fuchs NBB15-30GM50-E3-V1-3G-3D 225846, connect FAMAGA, the world's major producer of mechanized equipment. Our company has functioned for more than ten years - these are years of experience, which are depicted in the quality of spare parts and personalseparate attention to each orderer. We appreciate everyone, who joined with us - therefore, our regular buyers obtain the most acceptable purchase conditions and discounts on the industrial equipment market. Today, there are more than 3500 such customers, and we constantly make new agreements. More than 650 transactions are made per day, because FAMAGA operates all over the globe Germany, United Kingdom, Zambia, Namibia, North Korea, Sri Lanka, Armenia, Denmark, Poland, Rwanda, Qatar, Hungary, Egypt, Mongolia, Norway, Dominica, Lebanon, Madagascar, Grenada, Brazil, Macedonia, Burkina Faso, Iceland, Turkey, Liechtenstein, Liberia, Pakistan, Laos, Uganda, Gambia, Bolivia, Uzbekistan, Czech Republic, Sierra Leone, Libya, Thailand, Iran, Cameroon, Kazakhstan, Slovakia, Mozambique, Equatorial Guinea, Botswana, Andorra, Burundi, Jordan, Panama, Lithuania, Ghana. A well-developed logistics network and a partnership network allow us to conduct our items anywhere in the globe as soon as possible without disreputing product quality.
A special source of good name for FAMAGA is its personnel, each of whom contributes to our work. We accept into our team only professionals, who already have experience in the field of industrial equipment.
All products from FAMAGA are assured - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been shipped, and this number is amounting every day. We are pleased that customers choose FAMAGA again and again, and we are happy to make more advanced and technologically developed industrial equipment so as not to lower the bar.
To ask a question or book, get in touch with us or write to the online chat on our official website. You can also send a list of the desirable equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | PNP | |
Rated operating distance | 15 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 12.15 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.75 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 200 Hz | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le, 3 V | |
Operating current | 0 ... 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µ,A at 25 °C | |
No-load supply current | &le, 15 mA | |
Switching state indicator | Multihole-LED, yellow | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | Connector plug M12 x 1 , 4-pin | |
Housing material | brass, nickel-plated | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Equipment protection level Gc (nA) | ||
Certificate | PF 15CERT3754 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions | |
Special conditions | ||
Maximum operating current IL | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. | |
Maximum operating voltage UBmax | The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. | |
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=30 V, IL=200 mA | 54 °C (129.2 °F) | |
at UBmax=30 V, IL=100 mA | 57 °C (134.6 °F) | |
at UBmax=30 V, IL=50 mA | 58 °C (136.4 °F) | |
Equipment protection level Dc (tc) | ||
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
General | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=30 V, IL=200 mA | 54 °C (129.2 °F) | |
at UBmax=30 V, IL=100 mA | 57 °C (134.6 °F) | |
at UBmax=30 V, IL=50 mA | 58 °C (136.4 °F) | |
Equipment protection level Dc (tD) | ||
General | The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The maximum surface temperature has been determined in accordance with method A without a dust layer on the equipment. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! | |
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=30 V, IL=200 mA | 54 °C (129.2 °F) | |
at UBmax=30 V, IL=100 mA | 57 °C (134.6 °F) | |
at UBmax=30 V, IL=50 mA | 58 °C (136.4 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 3G, 3D |