We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ2-V3-N-V5
Part number
211638
Type
Inductive sensor
Description
Inductive sensor NJ2-V3-N-V5
Stock availability:
On request
If you are questing Pepperl+Fuchs NJ2-V3-N-V5 211638, contact FAMAGA, the world's dominant retailer of industrial equipment. Our company has existed for more than ten years - these are years of experience, which are expressed in the quality of outputs and personalseparate attention to each client. We value everyone, who collaborated with us - therefore, our regular consumers bring in the most attractive purchase forms and discounts on the machine made streamlined equipment market. At this moment, there are more than 4500 such customers, and we constantly form new agreements. More than 600 transactions are made per day, because FAMAGA operates all over the earth Germany, United Kingdom, Bahrain, Philippines, United Arab Emirates, Brunei, Cyprus, Czech Republic, Comoros, Kenya, Afghanistan, Vietnam, Burkina Faso, Netherlands, Canada, Djibouti, Bolivia, Chad, Japan, East Timor, Denmark, South Sudan, Fiji, Niger, Benin, Kuwait, Angola, Liechtenstein, Poland, Israel, Austria, Andorra, Costa Rica, Bosnia and Herzegovina, Iraq, Suriname, Zimbabwe, Estonia, Dominica, Mozambique, Slovakia, South Korea, Yemen, Jamaica, Pakistan. A well-developed logistics system and a partnership network cheer us to send our goods anywhere in the earth on-time without compromising product quality.
A particular source of honor for FAMAGA is its team members, each of whom contributes to common cause. We accept into our team only experts, who already have experience in the sphere of factory-made equipment.
All products from FAMAGA are verified - we are responsible for the cause of our work. Now, more than 10 million units of products have been delivered, and this bulk is ascending every day. We are glad that consumers choose FAMAGA again and again, and we strive to make more developed and technologically modern industrial equipment so as not to lower the bar.
To get some advice or book, phone us or write a message to the online chat on our official website. You can also send a list of the needful equipment to the email of corporation - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 2 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.25 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 1000 Hz | |
Hysteresis | typ. % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | &ge, 3 mA | |
Measuring plate detected | &le, 1 mA | |
Functional safety related parameters | ||
MTTFd | 11775 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0451 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | 4.8 mm Faston | |
Core cross-section | - | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 2-V3-N ... | |
Effective internal capacitance | max. 40 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 2-V3-N ... | |
Effective internal capacitance | max. 40 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 2-V3-N ... | |
Effective internal capacitance | max. 40 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |