We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NBN4-V3-E2-3G-3D
Part number
211278
Type
Inductive sensor
Description
Inductive sensor NBN4-V3-E2-3G-3D
Stock availability:
On request
If you are seeking Pepperl+Fuchs NBN4-V3-E2-3G-3D 211278, make contact with FAMAGA, the world's principle provider of industrial equipment. Our company has existed for more than ten years - these are years of experience, which are described in the quality of outcomes and individual attention to each client. We cherish everyone, who collaborated with us - thus, our regular clients get the most helpful purchase forms and discounts on the industrial equipment market. At this moment, there are more than 4 thousand such clients, and we constantly arrange new agreements. More than 750 transactions are made per day, because FAMAGA delivers all over the planet Germany, United Kingdom, Lebanon, Macedonia, Mongolia, Sri Lanka, Sudan, Nigeria, Kuwait, Australia, Finland, Uruguay, Laos, Bulgaria, Jordan, Liechtenstein, Mali, Lithuania, Saudi Arabia, Luxembourg, Andorra, Tonga, Afghanistan, Czech Republic, Fiji, Iraq, Tanzania, Uzbekistan, Turkey, Brunei, Suriname, Estonia, Antigua and Barbuda, North Korea, Malta, Ecuador, Malaysia, Moldova, The Gambia, Thailand, Latvia, Senegal, Equatorial Guinea, Ukraine, Rwanda. A advanced logistics system and a partnership network cheer us to conduct our goods anywhere in the planet as soon as possible without damaging product quality.
A particular source of good name for FAMAGA is its employees, each of whom contributes to common cause. We propose into our team only experts, who already have experience in the direction of industrial equipment.
All products from FAMAGA are ensured - we are responsible for the outcome of our work. At this moment, more than 10 million units of products have been provided, and this number is growing every day. We are happy that customers choose FAMAGA again and again, and we are glad to make more progressive and technologically developed industrial equipment so as stay in control.
To inquire or place an order, get in touch with us or write a message to the online chat on our official website. You can also dispatch a list of the necessary equipment to the email of our company - we will contact you ourselves with a made commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 4 mm | |
Installation | non-flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 3.24 mm | |
Reduction factor rAl | 0.35 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 500 Hz | |
Reverse polarity protection | yes | |
Short-circuit protection | pulsing | |
Voltage drop | &le, 3 V | |
Operating current | 0 ... 100 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.1 µ,A at 25 °C | |
No-load supply current | &le, 15 mA | |
Switching state indicator | LED, yellow | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 130 mm | |
Core cross-section | 0.14 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Equipment protection level Gc (nA) | ||
Certificate | PF 15CERT3754 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions | |
Special conditions | ||
Maximum operating current IL | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. | |
Maximum operating voltage UBmax | The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. | |
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=30 V, IL=100 mA | 41 °C (105.8 °F) | |
at UBmax=30 V, IL=50 mA | 42 °C (107.6 °F) | |
at UBmax=30 V, IL=25 mA | 42 °C (107.6 °F) | |
Equipment protection level Dc (tc) | ||
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
General | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=30 V, IL=100 mA | 41 °C (105.8 °F) | |
at UBmax=30 V, IL=50 mA | 42 °C (107.6 °F) | |
at UBmax=30 V, IL=25 mA | 42 °C (107.6 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 3G, 3D |