Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NCB10-30GM40-Z1-3G-3D
Part number
211272
Type
Inductive sensor
Description
Inductive sensor NCB10-30GM40-Z1-3G-3D
Stock availability:
On request
If you are looking for Pepperl+Fuchs NCB10-30GM40-Z1-3G-3D 211272, connect FAMAGA, the world's top vendor of factory-made equipment. Our company has lasted for more than ten years - these are years of experience, which are depicted in the quality of items and private attention to each consumer. We admire everyone, who joined with us - therefore, our regular consumers procure the most acceptable purchase forms and discounts on the industrial equipment market. At this moment, there are more than 4 thousand such consumers, and we constantly sign new agreements. More than 750 transactions are made per day, because FAMAGA operates all over the planet Germany, United Kingdom, Bhutan, Armenia, Lithuania, Cuba, Iraq, Laos, Suriname, Central African Republic, Botswana, Bangladesh, Greece, Thailand, Cameroon, Belize, Moldova, Namibia, Gambia, Albania, Tanzania, Eswatini, Indonesia, Austria, El Salvador, Chad, Ukraine, Azerbaijan, Australia, Kuwait, Syria, Peru, Malta, Denmark, Andorra, Jordan, Panama, Slovakia, Philippines, New Zealand, Brunei, Iran, Sierra Leone, India, Libya. A well-built logistics bond and a partnership network cheer us to dispatch our goods anywhere in the planet as soon as possible without discrediting product quality.
A particular source of dignity for FAMAGA is its team members, each of whom contributes to common cause. We request into our team only experts, who already have experience in the direction of industrial equipment.
All spare parts from FAMAGA are verified - we are responsible for the outcome of our work. At this moment, more than 10 million units of products have been provided, and this number is ascending every day. We are happy that customers choose FAMAGA again and again, and we are eager to make more progressive and technologically developed industrial equipment so as not to lower the bar.
To get some advice or place an order, get in touch with us or write a message to the online chat on our official website. You can also send a list of the necessary equipment to the email of our company - we will contact you ourselves with a made commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | Two-wire | |
Rated operating distance | 10 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 8.1 mm | |
Actual operating distance | 9 ... 11 mm typ. | |
Reduction factor rAl | 0.32 | |
Reduction factor rCu | 0.28 | |
Reduction factor r304 | 0.7 | |
Output type | 2-wire | |
Nominal ratings | ||
Operating voltage | 5 ... 60 V DC | |
Switching frequency | 0 ... 150 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Reverse polarity protection | reverse polarity tolerant | |
Short-circuit protection | pulsing | |
Voltage drop | &le, 5 V | |
Operating current | 2 ... 100 mA | |
Lowest operating current | 2 mA | |
Off-state current | 0 ... 0.5 mA typ. | |
Switching state indicator | all direction LED, yellow | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Cable version | PA | |
Core cross-section | 0.34 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Equipment protection level Gc (nA) | ||
Certificate | PF 15CERT3754 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions | |
Special conditions | ||
Maximum operating current IL | The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. | |
Maximum operating voltage UBmax | The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. | |
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=60 V, IL=100 mA | 53 °C (127.4 °F) | |
at UBmax=60 V, IL=50 mA | 58 °C (136.4 °F) | |
at UBmax=60 V, IL=25 mA | 61 °C (141.8 °F) | |
Equipment protection level Dc (tc) | ||
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
General | The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. | |
Special conditions | ||
Maximum permissible ambient temperature TUmax | dependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list. | |
at UBmax=60 V, IL=100 mA | 53 °C (127.4 °F) | |
at UBmax=60 V, IL=50 mA | 58 °C (136.4 °F) | |
at UBmax=60 V, IL=25 mA | 61 °C (141.8 °F) | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 3G, 3D |