Inductive sensor NCB10-30GM40-Z1-3G-3D Pepperl+Fuchs 211272
Inductive sensor NCB10-30GM40-Z1-3G-3D Pepperl+Fuchs 211272

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

NCB10-30GM40-Z1-3G-3D 211272 Pepperl+Fuchs Inductive sensor

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NCB10-30GM40-Z1-3G-3D

Part number

211272

Type

Inductive sensor

Description

Inductive sensor NCB10-30GM40-Z1-3G-3D

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NCB10-30GM40-Z1-3G-3D 211272

If you are looking for Pepperl+Fuchs NCB10-30GM40-Z1-3G-3D 211272, connect FAMAGA, the world's top vendor of factory-made equipment. Our company has lasted for more than ten years - these are years of experience, which are depicted in the quality of items and private attention to each consumer. We admire everyone, who joined with us - therefore, our regular consumers procure the most acceptable purchase forms and discounts on the industrial equipment market. At this moment, there are more than 4 thousand such consumers, and we constantly sign new agreements. More than 750 transactions are made per day, because FAMAGA operates all over the planet . A well-built logistics bond and a partnership network cheer us to dispatch our goods anywhere in the planet as soon as possible without discrediting product quality.

A particular source of dignity for FAMAGA is its team members, each of whom contributes to common cause. We request into our team only experts, who already have experience in the direction of industrial equipment.

All spare parts from FAMAGA are verified - we are responsible for the outcome of our work. At this moment, more than 10 million units of products have been provided, and this number is ascending every day. We are happy that customers choose FAMAGA again and again, and we are eager to make more progressive and technologically developed industrial equipment so as not to lower the bar.

To get some advice or place an order, get in touch with us or write a message to the online chat on our official website. You can also send a list of the necessary equipment to the email of our company - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features NCB10-30GM40-Z1-3G-3D 211272

General specifications
Switching functionNormally closed (NC)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ.
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Output type2-wire
Nominal ratings
Operating voltage5 ... 60 V DC
Switching frequency0 ... 150 Hz
Hysteresis1 ... 10 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop&le, 5 V
Operating current2 ... 100 mA
Lowest operating current2 mA
Off-state current0 ... 0.5 mA typ.
Switching state indicatorall direction LED, yellow
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 IEC 60947-5-2:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Cable versionPA
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP67
Cable
Bending radius> 10 x cable diameter
Equipment protection level Gc (nA)
CertificatePF 15CERT3754 X
CE marking[*PD-Z02586A*]
ATEX marking II 3G Ex nA IIC T6 Gc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-15:2010 Ignition protection category n Use is restricted to the following stated conditions
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=60 V, IL=100 mA53 °C (127.4 °F)
at UBmax=60 V, IL=50 mA58 °C (136.4 °F)
at UBmax=60 V, IL=25 mA61 °C (141.8 °F)
Equipment protection level Dc (tc)
CE marking[*PD-Z02586A*]
ATEX marking II 3D Ex tc IIIC T80°C Dc The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014 Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax Information can be taken from the following list.
at UBmax=60 V, IL=100 mA53 °C (127.4 °F)
at UBmax=60 V, IL=50 mA58 °C (136.4 °F)
at UBmax=60 V, IL=25 mA61 °C (141.8 °F)
General information
Use in the hazardous areasee instruction manuals
Category3G, 3D