Inductive sensor NCN30+U4+N0 Pepperl+Fuchs 184675
Inductive sensor NCN30+U4+N0 Pepperl+Fuchs 184675

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

NCN30+U4+N0 184675 Pepperl+Fuchs Inductive sensor

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NCN30+U4+N0

Part number

184675

Type

Inductive sensor

Description

  • Comfort series

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NCN30+U4+N0 184675

If you are looking for Pepperl+Fuchs NCN30+U4+N0 184675, catch up with FAMAGA, the world's chief distributor of factory-made equipment. Our company has operated for more than ten years - these are cycles of experience, which are outlined in the quality of products and special attention to each consumer. We appreciate everyone, who engaged with us - so, our regular consumers accept the most convenient purchase conditions and discounts on the factory-made equipment market. At present, there are more than 4500 such buyers, and we constantly compose new agreements. More than 650 agreements are achieved per day, because FAMAGA works all over the earth . A well-elaborated logistics bond and a partnership network allow us to send our elements anywhere in the earth on-time without undermining product quality.

A special source of honor for FAMAGA is its employees, each of whom contributes to common cause. We invite into our team only experts, who already have experience in the field of manufacturing equipment.

All spare parts from FAMAGA are verified - we are responsible for the cause of our work. At the moment, more than 10 million units of products have been shipped, and this amount is growing every day. We are glad that consumers choose FAMAGA again and again, and we are pleased to make more advanced and technologically innovative industrial equipment so as to stay on the top.

To get some advice or book, call us by phone or write to the online chat on our site. You can also direct a list of the needful equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.

Features NCN30+U4+N0 184675

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance30 mm
Installationnon-flush
Assured operating distance0 ... 24.3 mm
Actual operating distance27 ... 33 mm typ.
Reduction factor rAl 0.45
Reduction factor rCu 0.42
Reduction factor r304 0.79
Output type2-wire
Nominal ratings
Installation conditions
A10 mm
Nominal voltage8.2 V (Ri approx. 1 k&Omega,)
Switching frequency0 ... 150 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected&le, 1 mA
Switching state indicatorLED, yellow
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
FM approval
Control drawing116-0165
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0451
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Core cross-sectionup to 2.5 mm2
Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing materialPBT/metal
Sensing facePBT
Degree of protectionIP68
NoteTightening torque: 1.8 Nm (housing)
Equipment protection level Ga
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNCN30+U...+N0...
Effective internal capacitancemax. 110 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 160 µ,H , a cable length of 10 m is considered.
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Equipment protection level Gb
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNCN30+U...+N0...
Effective internal capacitancemax. 110 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 160 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Equipment protection level Da
CE marking[*PD-Z02585A*]
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNCN30+U...+N0...
Effective internal capacitancemax. 110 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 160 µ,H , a cable length of 10 m is considered.
General information
Use in the hazardous areasee instruction manuals
Category1G, 2G, 1D