We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NCN30+U4+N0
Part number
184675
Type
Inductive sensor
Description
Stock availability:
On request
If you are looking for Pepperl+Fuchs NCN30+U4+N0 184675, catch up with FAMAGA, the world's chief distributor of factory-made equipment. Our company has operated for more than ten years - these are cycles of experience, which are outlined in the quality of products and special attention to each consumer. We appreciate everyone, who engaged with us - so, our regular consumers accept the most convenient purchase conditions and discounts on the factory-made equipment market. At present, there are more than 4500 such buyers, and we constantly compose new agreements. More than 650 agreements are achieved per day, because FAMAGA works all over the earth Germany, United Kingdom, El Salvador, Hungary, Madagascar, Argentina, Singapore, Guinea-Bissau, Cyprus, Honduras, Armenia, Finland, Jordan, Belarus, Seychelles, Luxembourg, Comoros, Afghanistan, Benin, Bosnia and Herzegovina, Zambia, Pakistan, Liberia, Nicaragua, Burkina Faso, Russia, Guyana, Panama, Botswana, Georgia, North Korea, South Korea, Mauritania, Belize, Dominica, Fiji, Samoa, Croatia, Jamaica, India, Indonesia, Laos, Vietnam, Serbia, Kyrgyzstan, Zimbabwe, Namibia. A well-elaborated logistics bond and a partnership network allow us to send our elements anywhere in the earth on-time without undermining product quality.
A special source of honor for FAMAGA is its employees, each of whom contributes to common cause. We invite into our team only experts, who already have experience in the field of manufacturing equipment.
All spare parts from FAMAGA are verified - we are responsible for the cause of our work. At the moment, more than 10 million units of products have been shipped, and this amount is growing every day. We are glad that consumers choose FAMAGA again and again, and we are pleased to make more advanced and technologically innovative industrial equipment so as to stay on the top.
To get some advice or book, call us by phone or write to the online chat on our site. You can also direct a list of the needful equipment to the email of corporation - we will contact you ourselves with a ready-made commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 30 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 24.3 mm | |
Actual operating distance | 27 ... 33 mm typ. | |
Reduction factor rAl | 0.45 | |
Reduction factor rCu | 0.42 | |
Reduction factor r304 | 0.79 | |
Output type | 2-wire | |
Nominal ratings | ||
Installation conditions | ||
A | 10 mm | |
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 150 Hz | |
Hysteresis | 1 ... 15 typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | yes | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Switching state indicator | LED, yellow | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Electromagnetic compatibility | NE 21:2007 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0451 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Mechanical specifications | ||
Connection type | screw terminals | |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % | |
Core cross-section | up to 2.5 mm2 | |
Minimum core cross-section | without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2 | |
Maximum core cross-section | without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2 | |
Housing material | PBT/metal | |
Sensing face | PBT | |
Degree of protection | IP68 | |
Note | Tightening torque: 1.8 Nm (housing) | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCN30+U...+N0... | |
Effective internal capacitance | max. 110 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 160 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCN30+U...+N0... | |
Effective internal capacitance | max. 110 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 160 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCN30+U...+N0... | |
Effective internal capacitance | max. 110 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 160 µ,H , a cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |