Transmitter Power Supply HiD2029 Pepperl+Fuchs 121492
Transmitter Power Supply HiD2029 Pepperl+Fuchs 121492

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

HiD2029 121492 Pepperl+Fuchs Transmitter Power Supply

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

HiD2029

Part number

121492

Type

Transmitter Power Supply

Description

  • 1-channel isolated barrier
  • 24 V DC supply (bus powered)
  • 2-wire SMART transmitters or current sources
  • Output for 4 mA ... 20 mA or 1 V ... 5 V
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications HiD2029 121492

This isolated barrier is used for intrinsic safety applications. It provides a fully floating supply to power 2-wire SMART transmitters in the hazardous area, and repeats the current to drive a safe area load. It is also used with 2-wire current sources. Digital signals may be superimposed on the analog values in the hazardous or safe area, which are transferred bidirectionally. A separate fault output on the bus is signaled if the input signal is outside the range 0.2 mA ... 24 mA. The fault conditions can be monitored via a Fault Indication Board. This module mounts on a HiD Termination Board.

Features HiD2029 121492

General specifications
Signal typeAnalog input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionSL1: 1a(-), 1b(-), 2a(+), 2b(+)
Rated voltage20.4 ... 30 V DC bus powered via Termination Board
Rated current60 mA at 24 V, 20 mA output
Power dissipation1.05 W at 24 V
Input
Connection sidefield side
ConnectionSL2: 5a(+), 5b, 7a(-)
Input current4 ... 20 mA , current limit 26 mA
Input resistance40 &Omega, , for current source
Ripple10 mV eff
Voltagemin. 15.5 V at 20 mA
Communicationpass-through of HART signal to safe area The current sink terminals 4 and 7 do not pass the HART signal to safe area.
Output
Connection sidecontrol side
ConnectionSL1: 8a(+), 7a(-)
Load0 ... 650 &Omega,
Output signal4 ... 20 mA or 1 ... 5 V (on 250 &Omega,, 0.1 % internal shunt)
Ripple10 mV eff on a load of 250 &Omega,
Response time70 ms , 10 ... 90 % step change
Signal levelno fault: 1 mA ... 23.5 mA input current fault detection: 24 mA input current
Fault indication output
ConnectionSL1: 6b
Output typeopen collector transistor fault bus signal
Transfer characteristics
Calibrated accuracy< ± 0.1 % of full-scale value (current output)
Influence of temperature< ± 0.01 %/ K
Frequency rangecommunication channel: 0.5 ... 40 kHz within 3 db, (-6 db at 100 kHz), Tx to output and output to Tx, suitable for use with SMART transmitters using HART or similar protocol
Influence of load< ± 0.1 % of full-scale value from 0 ... 650 &Omega,
Linearity< ± 0.05 % of full-scale value
Indicators/settings
Display elementsLEDs
Control elementsDIP-switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2006 For further information see system description.
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Massapprox. 140 g
Dimensions18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)
Mountingon Termination Board
Data for application in connection with hazardous areas
EU-Type Examination CertificateCESI 02 ATEX 086
Marking II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC
CertificatePF 11 CERT 2109 X
Marking II 3G Ex nA IIC T4 Gc [device in zone 2]
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
CSA approval
Control drawing366-005CS-12B (cCSAus)
IECEx approvalIECEx TUN 04.0012
Approved for[Ex ia] IIC