We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
SJ1,8-N-Y16109
Part number
106573
Type
Inductive sensor
Description
Inductive slot sensor SJ1,8-N-Y16109
Stock availability:
On request
If you are inspecting Pepperl+Fuchs SJ1,8-N-Y16109 106573, communicate with FAMAGA, the world's primary producer of machine made equipment. Our company has advanced for more than ten years - these are ages of experience, which are portrayed in the quality of items and individual attention to each customer. We cherish everyone, who conspired with us - so, our regular clients bring in the most helpful purchase forms and discounts on the factory-made equipment market. Today, there are more than 4 thousand such buyers, and we constantly form new agreements. More than 600 affairs are settled per day, because FAMAGA works all over the earth Germany, United Kingdom, Dominica, Afghanistan, Tunisia, Poland, Ghana, Honduras, Nepal, Eswatini, Romania, Luxembourg, Japan, Georgia, Mexico, Yemen, Sweden, Cape Verde, Sierra Leone, Monaco, Kyrgyzstan, Indonesia, Zimbabwe, Serbia, Switzerland, Hungary, Togo, Albania, Mauritius, Nicaragua, Belarus, Botswana, Paraguay, Qatar, Algeria, Tajikistan, Macedonia, Swaziland, Brazil, Samoa, Ireland, Madagascar, Philippines, Mauritania, Croatia. A well-developed logistics bond and a partnership network guide us to conduct our products anywhere in the earth quickly without undermining product quality.
A particular source of honor for FAMAGA is its employees, each of whom contributes to common cause. We propose into our team only experts, who already have experience in the direction of machine made streamlined equipment.
All goods from FAMAGA are ensured - we are responsible for the result of our work. At this moment, more than 10 million units of products have been provided, and this amount is increasing every day. We are happy that buyers choose FAMAGA again and again, and we strive to make more developed and technologically modern industrial equipment so as to stay on the top.
To ask a question or make a request, phone us or send a message to the online chat on our site. You can also forward a list of the needful equipment to the email of firm - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Slot width | 2 mm | |
Depth of immersion (lateral) | 4 ... 5 typ. 4.5 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 5000 Hz | |
Hysteresis | 0.3 ... 0.6 mm | |
Current consumption | ||
Measuring plate not detected | min. 4 mA at nominal voltage | |
Measuring plate detected | &le, 0.65 mA at nominal voltage | |
Functional safety related parameters | ||
MTTFd | 5270 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | flexible leads | |
Housing material | Crastin (PBTB) | |
Degree of protection | IP67 | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Gb , Da , Mb | |
Equipment protection level Gb | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | SJ1,8-N-Y... | |
ATEX certificate | PTB 99 ATEX 2219 X | |
ATEX marking | II 2G Ex ia IIC T6&hellip,T1 Gb | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx PTB 11.0091X | |
IECEx marking | Ex ia IIC T6...T1 Gb | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW , T6 : 67 °C (152.6 °F) T5 : 82 °C (179.6 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW , T6 : 45 °C (113 °F) T5 : 60 °C (140 °F) T4 : 78 °C (172.4 °F) T3 : 78 °C (172.4 °F) T2 : 78 °C (172.4 °F) T1 : 78 °C (172.4 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW , T6 : 30 °C (86 °F) T5 : 45 °C (113 °F) T4 : 57 °C (134.6 °F) T3 : 57 °C (134.6 °F) T2 : 57 °C (134.6 °F) T1 : 57 °C (134.6 °F) | |
Equipment protection level Da | ||
Type of protection | intrinsic safety | |
CE marking | [*PD-Z02585A*] | |
Certificates | ||
Appropriate type | SJ1,8-N-Y... | |
ATEX certificate | PTB 99 ATEX 2219 X | |
ATEX marking | II 1D Ex ia IIIC T135°C Da | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
IECEx certificate | IECEx PTB 11.0091X | |
IECEx marking | Ex ia IIIC T135°C Da | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 78 °C (172.4 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 57 °C (134.6 °F) | |
Equipment protection level Mb | ||
Type of protection | intrinsic safety | |
Certificates | ||
Appropriate type | SJ1,8-N-Y... | |
IECEx certificate | IECEx PTB 11.0091X | |
IECEx marking | Ex ia I Mb | |
Standards | IEC 60079-0:2011 , IEC 60079-11:2011 | |
Effective internal capacitance | max. 30 nF A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H A cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at Ui = 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F) at Ui = 16 V , Ii = 52 mA , Pi = 169 mW : 78 °C (172.4 °F) at Ui = 16 V , Ii = 76 mA , Pi = 242 mW : 57 °C (134.6 °F) | |
General information | ||