Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ5-11-N-5M
Part number
106435
Type
Inductive sensor
Description
Inductive sensor NJ5-11-N-5M
Stock availability:
On request
If you are seeking Pepperl+Fuchs NJ5-11-N-5M 106435, catch up with FAMAGA, the world's main distributor of mechanized equipment. Our company has worked for more than ten years - these are ages of experience, which are portrayed in the quality of merchandises and particular attention to each buyer. We esteem everyone, who joined with us - therefore, our regular purchasers get the most beneficial purchase forms and discounts on the industrial equipment market. At this time, there are more than 4 thousand such consumers, and we constantly form new agreements. More than 650 proceedings are resolved per day, because FAMAGA works all over the planet Germany, United Kingdom, France, Palestine, Slovakia, Cuba, Oman, Cameroon, Turkmenistan, Libya, Kuwait, Serbia, Egypt, Netherlands, Azerbaijan, Japan, Croatia, Yemen, Togo, Peru, Monaco, Angola, India, Nepal, Afghanistan, The Bahamas, Madagascar, Suriname, Cape Verde, Denmark, Samoa, Liechtenstein, East Timor, Jamaica, Poland, Albania, Pakistan, Montenegro, Bolivia, Iraq, Dominica, Haiti, Vietnam, Belarus, The Gambia, Burkina Faso. A well-developed logistics series and a partnership network let us to ship our products anywhere in the earth as soon as possible without damaging product quality.
A special source of dignity for FAMAGA is its employees, each of whom contributes to our work. We call into our team only professionals, who already have experience in the sphere of machine made streamlined equipment.
All outputs from FAMAGA are affirmed - we are responsible for the result of our work. Now, more than 10 million units of products have been provided, and this number is amounting every day. We are happy that buyers choose FAMAGA again and again, and we strive to make more advanced and technologically modern industrial equipment so as to stay on the top.
To get some advice or make a request, call us by phone or write a message to the online chat on our site. You can also direct a list of the needful equipment to the email of our company - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 5 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 4.05 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Switching frequency | 0 ... 3000 Hz | |
Hysteresis | typ. % | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Functional safety related parameters | ||
MTTFd | 11774 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 5 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PVDF | |
Sensing face | PVDF | |
Degree of protection | IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 2G Ex ia IIC T6&hellip,T1 Gb The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 5-11-N... | |
Effective internal capacitance | max. 45 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 5-11-N... | |
Effective internal capacitance | max. 45 µ,F A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H A cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G |