We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ1,5-18GM-N-D
Part number
106342
Type
Inductive sensor
Description
Inductive sensor NJ1,5-18GM-N-D
Stock availability:
On request
If you are looking for Pepperl+Fuchs NJ1,5-18GM-N-D 106342, get in touch with FAMAGA, the world's prime vendor of mechanized equipment. Our company has worked for more than ten years - these are years of experience, which are depicted in the quality of outputs and special attention to each buyer. We respect everyone, who conspired with us - hence, our regular buyers get the most flexible purchase forms and discounts on the manufacturing equipment market. Today, there are more than 4 thousand such consumers, and we constantly compose new agreements. More than 750 affairs are settled per day, because FAMAGA works all over the globe Germany, United Kingdom, Andorra, Eswatini, Bahrain, Sierra Leone, Qatar, Togo, Guyana, Slovakia, Zambia, Honduras, Turkmenistan, Fiji, Kuwait, Eritrea, Zimbabwe, Estonia, Malaysia, Belarus, Liechtenstein, Latvia, Nepal, Serbia, United States, Croatia, Bulgaria, Tonga, Peru, Georgia, Tanzania, Brunei, Kyrgyzstan, Sweden, Lithuania, Cape Verde, Egypt, El Salvador, Morocco, Dominica, Cyprus, Afghanistan, Samoa, Luxembourg, Greece, Comoros, Jordan, Ireland, Tunisia. A advanced logistics connection and a partnership network guide us to send our goods anywhere in the world with no delay without discrediting product quality.
A particular source of dignity for FAMAGA is its workers, each of whom contributes to common cause. We invite into our team only experts, who already have experience in the range of industrial equipment.
All spare parts from FAMAGA are assured - we are responsible for the result of our work. Nowadays, more than 10 million units of products have been shipped, and this quantity is rising every day. We are happy that customers choose FAMAGA again and again, and we are pleased to make more progressive and technologically modern industrial equipment so as to stay on the top.
To get some advice or place an order, get in touch with us or send a message to the online chat on our site. You can also dispatch a list of the required equipment to the email of organization - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 1.5 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.22 mm | |
Reduction factor rAl | 0 | |
Reduction factor rCu | 0 | |
Reduction factor r304 | 0.55 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 400 Hz | |
Hysteresis | typ. % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Limit data | ||
Operating pressure | 350 bar (5076.4 psi) | |
Functional safety related parameters | ||
MTTFd | 10880 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
Ambient conditions | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 2 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | Ceramic | |
Degree of protection | IP66 / IP68 | |
Cable | ||
Cable diameter | 4.8 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 2G Ex ia IIC T6&hellip,T1 Gb The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ1,5-18GM-N-D.. | |
Effective internal capacitance | max. 50 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 60 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ1,5-18GM-N-D.. | |
Effective internal capacitance | max. 50 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 60 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G, 1D |