We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
SJ3,5-N
Part number
105910
Type
Inductive sensor
Description
Stock availability:
On request
If you are seeking Pepperl+Fuchs SJ3,5-N 105910, communicate with FAMAGA, the world's central vendor of mechanized equipment. Our company has operated for more than ten years - these are years of experience, which are portrayed in the quality of products and particular attention to each client. We admire everyone, who engaged with us - hence, our regular buyers procure the most helpful purchase terms and discounts on the manufacturing equipment market. Nowadays, there are more than 4500 such purchasers, and we constantly sign new agreements. More than 750 contracts are concluded per day, because FAMAGA supplies all over the earth Germany, United Kingdom, Lebanon, Albania, Samoa, Grenada, Laos, Moldova, Denmark, Yemen, Mozambique, Chad, Belize, Panama, Tanzania, Slovenia, Guyana, Chile, Mongolia, Thailand, United Arab Emirates, Equatorial Guinea, Saudi Arabia, Israel, Ghana, Iceland, Zimbabwe, Peru, Rwanda, India, Pakistan, Sierra Leone, Suriname, Burundi, Seychelles, Slovakia, Senegal, Ukraine, Angola, Cameroon, Zambia, Sudan, Libya, Hungary, Comoros, Uganda, Djibouti, Montenegro, Cape Verde. A well-built logistics network and a partnership network help us to send our goods anywhere in the earth with no delay without discrediting product quality.
A particular source of repute for FAMAGA is its personnel, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the direction of machine made streamlined equipment.
All spare parts from FAMAGA are affirmed - we are responsible for the aftereffect of our work. At this moment, more than 10 million units of products have been provided, and this quantity is amounting every day. We are glad that clients choose FAMAGA again and again, and we are glad to make more progressive and technologically advanced industrial equipment so as keep on top of it.
To request or make a request, get in touch with us or write a message to the online chat on our site. You can also forward a list of the needful equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Slot width | 3.5 mm | |
Depth of immersion (lateral) | 5 ... 7 mm , typ. 6 mm | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Operating voltage | 5 ... 25 V | |
Switching frequency | 0 ... 3000 Hz | |
Hysteresis | 0.41 ... 0.6 mm | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | &ge, 3 mA at nominal voltage | |
Measuring plate detected | &le, 1 mA at nominal voltage | |
Functional safety related parameters | ||
MTTFd | 8415 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0453 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | flexible leads LiY , 500 mm | |
Core cross-section | 0.14 mm2 | |
Housing material | PBT/PPS | |
Degree of protection | IP67 | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | SJ3,5-...-N... | |
Effective internal capacitance | max. 50 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 250 µ,H , a cable length of 10 m is considered. | |
Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | SJ3,5-...-N... | |
Effective internal capacitance | max. 50 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 250 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | SJ3,5-...-N... | |
Effective internal capacitance | max. 50 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 250 µ,H , a cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |