FN-LB-I Pepperl+Fuchs 098918
 FN-LB-I Pepperl+Fuchs 098918

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

FN-LB-I 098918 Pepperl+Fuchs

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

FN-LB-I

Part number

098918

Description

  • 1-channel
  • Field mount module
  • ½, NPT thread
  • Stainless steel housing
  • Max. surge current (8/20 µ,s) 20 kA
  • 500 V isolation from earth
  • Suitable for hazardous area

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications FN-LB-I 098918

This Surge Protection Barrier limits induced transients of different origin (e. g. lightning stroke, switching impulse, etc.). This is achieved by diverting the transient current to ground and limiting the signal line voltage to a safe level for the duration of the surge. This barrier provides 85 V line-to-line and 500 V line-to-ground clamping voltage for the protected instruments. It also protects instruments that have less than 500 V isolation-to-ground. It is installed in an available conduit or cable gland opening like those found on most process transmitters. For additional information, refer to the manual and www.pepperl-fuchs.com. Note: Surge Protection Barriers must always be connected to a solid and effective ground and be at the same equipotential level as the instrument it is protecting. The ground system must comply with all applicable regulations.

Features FN-LB-I 098918

Product Description
NPT1/2 thread
General specifications
Number of protected signal lines1
Supply
Rated voltage&le, 48 V
Rated current&le, 250 mA
Leakage current&le, 5 µ,A
On-state voltage&le, 85 V
Ground insulation&ge, 500 V breakdown voltage
Electrical specifications
Total discharge current (8/20 µ,s)20 kA
Conformity
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-30 ... 60 °C (-22 ... 140 °F) For usage in hazardous area observe EC-type examination certificate.
Mechanical specifications
Housing materialStainless steel 1.4401 (AISI 316) surface all over polished
Degree of protectionIP67
Cable
Length0.3 m
Massapprox. 200 g
DimensionsAF22 x 77 mm (0.9 x 3 inch)
MountingNPT1/2 thread
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 00 ATEX 2175
Marking II 2G EEx ia IIC T6
Voltage50 V
Maximum leakage current10 kA line to ground (common), 5 kA line to line (differential) in accordance to IEC 60-2
Nominal response time
Symmetrical1 ns
Asymmetric100 ns
Bandwidth&ge, 40 kHz
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012
International approvals
CSA approval
Control drawing116-0187 (cCSAus)
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.