We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NCB2-12GM40-E2-5M-3G-3D
Part number
310842
Type
Inductive sensor
Description
Stock availability:
On request
If you are questing Pepperl+Fuchs NCB2-12GM40-E2-5M-3G-3D 310842, connect FAMAGA, the world's foremost vendor of machine made equipment. Our company has advanced for more than ten years - these are cycles of experience, which are described in the quality of spare parts and personalseparate attention to each customer. We understand everyone, who engaged with us - thus, our regular customers bring in the most convenient purchase terms and discounts on the machine made streamlined equipment market. Now, there are more than 4 thousand such buyers, and we constantly arrange new agreements. More than 700 contracts are concluded per day, because FAMAGA works all over the world Germany, United Kingdom, Bhutan, Burma, Equatorial Guinea, Tonga, Kenya, Oman, Tanzania, Belize, Botswana, Turkmenistan, Syria, Palestine, Nigeria, North Korea, Niger, Guyana, Paraguay, Central African Republic, Chad, Netherlands, Chile, Liechtenstein, Bolivia, Denmark, Gambia, Bosnia and Herzegovina, Czech Republic, Kazakhstan, Burundi, Kyrgyzstan, Madagascar, Bangladesh, New Zealand, Burkina Faso, Jordan, Panama, Uganda, Jamaica, Austria, Rwanda, Bulgaria, The Gambia, Mongolia, Poland. A well-shaped logistics connection and a partnership network help us to dispatch our units anywhere in the globe promptly without compromising product quality.
A special source of honor for FAMAGA is its personnel, each of whom contributes to our work. We accept into our team only professionals, who already have experience in the field of factory-made equipment.
All spare parts from FAMAGA are guaranteed - we are responsible for the result of our work. At the moment, more than 10 million units of products have been supplied, and this bulk is growing every day. We are happy that purchasers choose FAMAGA again and again, and we are glad to make more exceptional and technologically advanced industrial equipment so as to stay on the top.
To ask a question or book, contact us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally open (NO) | |
Output type | PNP | |
Rated operating distance | 2 mm | |
Installation | flush | |
Output polarity | DC | |
Assured operating distance | 0 ... 1.62 mm | |
Actual operating distance | 1.8 ... 2.2 mm typ. 2 mm | |
Reduction factor rAl | 0.3 | |
Reduction factor rCu | 0.17 | |
Reduction factor r304 | 0.67 | |
Reduction factor rBrass | 0.35 | |
Output type | 3-wire | |
Nominal ratings | ||
Operating voltage | 10 ... 30 V DC | |
Switching frequency | 0 ... 2500 Hz | |
Hysteresis | 3 ... 15 typ. 6 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | pulsing | |
Voltage drop | &le, 3 V | |
Voltage drop at IL | ||
Voltage drop IL = 200 mA, switching element on | 1 ... 2 V typ. 1.5 V | |
Operating current | &le, 200 mA | |
Off-state current | 0 ... 0.5 mA typ. 0.01 mA | |
No-load supply current | &le, 15 mA | |
Time delay before availability | &le, 100 ms | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1507 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 5 m | |
Core cross-section | 0.34 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Cable diameter | 4.6 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Data for application in connection with hazardous areas | ||
Equipment protection level | Gc (nA) , Dc | |
Equipment protection level Gc (nA) | ||
Type of protection | n | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF15CERT3754X | |
ATEX marking | II 3G Ex nA IIC T6 Gc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
Surge protection | The protection against transient overvoltage with amplitude U is realized. U = 500 V at 1.2/50 µ,s, 500 &Omega, | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 °C (109.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 53 °C (127.4 °F) | |
Equipment protection level Dc | ||
Type of protection | Protection by enclosure tc | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF15CERT3774X | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-31:2014 | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output current IAmax , maximum analog output voltage UAmax | |
Maximum permissible ambient temperature | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 °C (109.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 53 °C (127.4 °F) | |
General information | ||
Scope of delivery | 2 self locking nuts in scope of delivery | |
Use in the hazardous area | see instruction manuals |