Inductive sensor NCB2-12GM40-E2-5M-3G-3D Pepperl+Fuchs 310842
Inductive sensor NCB2-12GM40-E2-5M-3G-3D Pepperl+Fuchs 310842

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

NCB2-12GM40-E2-5M-3G-3D 310842 Pepperl+Fuchs Inductive sensor

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NCB2-12GM40-E2-5M-3G-3D

Part number

310842

Type

Inductive sensor

Description

  • Comfort series
  • ATEX-approval for zone 2 and zone 22

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NCB2-12GM40-E2-5M-3G-3D 310842

If you are questing Pepperl+Fuchs NCB2-12GM40-E2-5M-3G-3D 310842, connect FAMAGA, the world's foremost vendor of machine made equipment. Our company has advanced for more than ten years - these are cycles of experience, which are described in the quality of spare parts and personalseparate attention to each customer. We understand everyone, who engaged with us - thus, our regular customers bring in the most convenient purchase terms and discounts on the machine made streamlined equipment market. Now, there are more than 4 thousand such buyers, and we constantly arrange new agreements. More than 700 contracts are concluded per day, because FAMAGA works all over the world . A well-shaped logistics connection and a partnership network help us to dispatch our units anywhere in the globe promptly without compromising product quality.

A special source of honor for FAMAGA is its personnel, each of whom contributes to our work. We accept into our team only professionals, who already have experience in the field of factory-made equipment.

All spare parts from FAMAGA are guaranteed - we are responsible for the result of our work. At the moment, more than 10 million units of products have been supplied, and this bulk is growing every day. We are happy that purchasers choose FAMAGA again and again, and we are glad to make more exceptional and technologically advanced industrial equipment so as to stay on the top.

To ask a question or book, contact us or send a message to the online chat on our site. You can also send a list of the desirable equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features NCB2-12GM40-E2-5M-3G-3D 310842

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance2 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ. 2 mm
Reduction factor rAl 0.3
Reduction factor rCu 0.17
Reduction factor r304 0.67
Reduction factor rBrass 0.35
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 2500 Hz
Hysteresis3 ... 15 typ. 6 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop&le, 3 V
Voltage drop at IL
Voltage drop IL = 200 mA, switching element on1 ... 2 V typ. 1.5 V
Operating current&le, 200 mA
Off-state current0 ... 0.5 mA typ. 0.01 mA
No-load supply current&le, 15 mA
Time delay before availability&le, 100 ms
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1507 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typecable PVC , 5 m
Core cross-section0.34 mm2
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
Cable
Cable diameter4.6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Data for application in connection with hazardous areas
Equipment protection levelGc (nA) , Dc
Equipment protection level Gc (nA)
Type of protectionn
CE marking[*PD-Z02586A*]
Certificates
ATEX certificatePF15CERT3754X
ATEX marking II 3G Ex nA IIC T6 Gc
StandardsEN 60079-0:2012+A11:2013 , EN 60079-15:2010
Surge protectionThe protection against transient overvoltage with amplitude U is realized. U = 500 V at 1.2/50 µ,s, 500 &Omega,
Possible characteristicsmaximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 °C (109.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 53 °C (127.4 °F)
Equipment protection level Dc
Type of protectionProtection by enclosure tc
CE marking[*PD-Z02586A*]
Certificates
ATEX certificatePF15CERT3774X
ATEX marking II 3D Ex tc IIIC T80°C Dc
StandardsEN 60079-0:2012+A11:2013 , EN 60079-31:2014
Possible characteristicsmaximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output current IAmax , maximum analog output voltage UAmax
Maximum permissible ambient temperatureAlso observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at UBmax = 30 V , IL = 200 mA : 43 °C (109.4 °F) at UBmax = 30 V , IL = 100 mA : 50 °C (122 °F) at UBmax = 30 V , IL = 50 mA : 53 °C (127.4 °F)
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals