Supply | ||
---|---|---|
Rated voltage | 7 ... 32 V DC | |
Rated current | < 1 mA , max. 25 mA | |
Electrical specifications | ||
Output rated operating current | 3.2 ... 25 mA | |
Supply | loop power for field devices voltage: 1 ... 2.5 V DC, adjustable in steps of 0.5 V | |
Input | ||
Connection | - 5 wires, 600 mm long, exiting from male thread NPT1/2 - 1 external grounding point | |
HART communication | ||
Protocol | HART 7.1, backward compatible | |
Number of devices | up to 8 HART field devices (depending on installation) | |
Output | ||
Interface | internal antenna | |
Communication | WirelessHART specifications - physical layer: IEEE 802.15.4.2006 - frequency band: 2.4 GHz (ISM band, licence free) - maximum transmit power: +10 dBm - outdoor transmission range: 235 m - communication standard: WirelessHART | |
Directive conformity | ||
Radio and telecommunication terminal equipment | The usage of 2.4 GHz equipment is bound to local restrictions. Ensure that restrictions allow usage of this product before commisioning. | |
Directive 2014/53/EU | EN 300 328 V2.1.1:2016 EN 301 489-1 V2.2.0:2017 EN 301 489-17 V3.2.0:2017 | |
FCC CFR47 Part 15 B and C | ANSI C63.4-2003 , FCC ID: X89-WA1101 | |
Conformity | ||
Degree of protection | IEC 60529:2013 | |
Ambient conditions | ||
Ambient temperature | temperature class T5: -40 ... 85 °C (-40 ... 185 °F) temperature class T6: -40 ... 75 °C (-40 ... 167 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | max. 100 % | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Material | Aluminum alloy with polyurethane enamel paint | |
Mass | 460 g | |
Dimensions | 60.8 x 60.8 x 100 mm (l x w x h) | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | FM 17 ATEX 0046 X | |
Marking | II 2 G Ex db IIC T6...T5 Gb II 2 D Ex tb IIIC T95°C Db | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-1:2014 , EN 60079-31:2014 | |
International approvals | ||
FM approval | FM 17 NUS 0010 FM 17 US 0191 X | |
Control drawing | 116-0425 (cFMus) | |
Approved for | XP Class I, II, III, Division 1, Groups A-G Class I, Zone 1, AEx db IIC T6...T5 Gb Zone 21, AEx tb IIIC T95°C Db | |
CSA approval | FM 17 NCA 0004 FM 17 CA 0102 X | |
Control drawing | 116-0425 (cFMus) | |
Approved for | XP Class I, II, III, Division 1, Groups A-G Ex db IIC T6...T5 Gb Ex tb IIIC T95°C Db | |
IECEx approval | ||
IECEx certificate | IECEx FMG 17.0020X | |
IECEx marking | Ex db IIC T6...T5 Gb , Ex tb IIIC T95°C Db | |
Standards | IEC 60079-0:2011 , IEC 60079-1:2014 , IEC 60079-31:2013 | |
General information | ||