Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ6-22-N-5M
Part number
106458
Type
Inductive sensor
Description
Inductive sensor NJ6-22-N-5M
Stock availability:
On request
If you are questing Pepperl+Fuchs NJ6-22-N-5M 106458, contact FAMAGA, the world's principle retailer of industrial equipment. Our company has lasted for more than ten years - these are cycles of experience, which are outlined in the quality of merchandises and personalseparate attention to each consumer. We appreciate everyone, who engaged with us - therefore, our regular customers obtain the most favorable purchase forms and discounts on the industrial equipment market. At this moment, there are more than 4 thousand such consumers, and we constantly compose new agreements. More than 650 transactions are made per day, because FAMAGA works all over the world Germany, United Kingdom, Bahrain, Mexico, Philippines, Dominica, Equatorial Guinea, Cyprus, Denmark, Portugal, Canada, Algeria, Kuwait, Palestine, Serbia, South Sudan, Eritrea, The Bahamas, Swaziland, Uzbekistan, Namibia, Egypt, Lithuania, The Gambia, Belarus, Mauritius, Sweden, Bolivia, Pakistan, Belize, Zimbabwe, Russia, Djibouti, Czech Republic, Nicaragua, Kiribati, United States, Vietnam, Poland, Burkina Faso, Jordan, East Timor, North Korea, Mauritania, Malaysia, Madagascar, India. A advanced logistics link and a partnership network allow us to deliver our units anywhere in the planet on-time without compromising product quality.
A specific source of dignity for FAMAGA is its workers, each of whom contributes to our work. We accept into our team only specialists, who already have experience in the field of manufacturing equipment.
All merchandises from FAMAGA are guaranteed - we are responsible for the result of our work. At the moment, more than 10 million units of products have been delivered, and this number is growing every day. We are happy that purchasers choose FAMAGA again and again, and we are pleased to make more advanced and technologically modern industrial equipment so as to stay on the top.
To get some advice or order, call us by phone or write to the online chat on our site. You can also send a list of the necessary equipment to the email of our company - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 6 mm | |
Installation | flush | |
Assured operating distance | 0 ... 4.86 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Switching frequency | 0 ... 2000 Hz | |
Hysteresis | typ. % | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Functional safety related parameters | ||
MTTFd | 4566 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 IEC 60947-5-2:2007 | |
Approvals and certificates | ||
FM approval | ||
Control drawing | 116-0165 | |
UL approval | cULus Listed, General Purpose | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 5 m | |
Core cross-section | 0.75 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP68 | |
Cable | ||
Bending radius | > 10 x cable diameter | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 2G Ex ia IIC T6&hellip,T1 Gb The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 6-22-N... | |
Effective internal capacitance | max. 130 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. | |
Equipment protection level Gc (ic) | ||
Certificate | PF 13 CERT 2895 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex ic IIC T6&hellip,T1 Gc The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection category ic Use is restricted to the following stated conditions | |
Effective internal capacitance | max. 130 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , A cable length of 10 m is considered. | |
Special conditions | ||
for Pi=34 mW, Ii=25 mA, T6 | 70 °C (158 °F) | |
for Pi=34 mW, Ii=25 mA, T5 | 85 °C (185 °F) | |
for Pi=34 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) | |
for Pi=64 mW, Ii=25 mA, T6 | 69 °C (156.2 °F) | |
for Pi=64 mW, Ii=25 mA, T5 | 84 °C (183.2 °F) | |
for Pi=64 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) | |
for Pi=169 mW, Ii=52 mA, T6 | 51 °C (123.8 °F) | |
for Pi=169 mW, Ii=52 mA, T5 | 66 °C (150.8 °F) | |
for Pi=169 mW, Ii=52 mA, T4-T1 | 80 °C (176 °F) | |
for Pi=242 mW, Ii=76 mA, T6 | 39 °C (102.2 °F) | |
for Pi=242 mW, Ii=76 mA, T5 | 54 °C (129.2 °F) | |
for Pi=242 mW, Ii=76 mA, T4-T1 | 61 °C (141.8 °F) | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 6-22-N... | |
Effective internal capacitance | max. 130 µ,F A cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H A cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 2G, 3G |