We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ2-V3-N-0,075M
Part number
250497
Type
Inductive sensor
Description
Inductive sensor NJ2-V3-N-0,075M
Stock availability:
On request
If you are inspecting Pepperl+Fuchs NJ2-V3-N-0,075M 250497, reach FAMAGA, the world's top vendor of streamlined equipment. Our company has worked for more than ten years - these are ages of experience, which are outlined in the quality of products and particular attention to each buyer. We admire everyone, who collaborated with us - therefore, our regular purchasers get the most acceptable purchase conditions and discounts on the industrial equipment market. Nowadays, there are more than 3500 such customers, and we constantly make new agreements. More than 650 agreements are achieved per day, because FAMAGA delivers all over the earth Germany, United Kingdom, Monaco, Switzerland, Chad, Madagascar, North Korea, Swaziland, Thailand, India, Papua New Guinea, Burma, Djibouti, Tonga, Zimbabwe, Poland, United States, Grenada, Chile, Japan, Fiji, Eritrea, Mexico, Burundi, Liechtenstein, Samoa, Mongolia, Sweden, Nicaragua, Czech Republic, Guatemala, Mozambique, Syria, Burkina Faso, Bangladesh, Georgia, Tunisia, Morocco, Norway, Paraguay, Mauritania, Bulgaria, United Arab Emirates, Brunei, Albania, Sudan. A well-built logistics connection and a partnership network cheer us to deliver our products anywhere in the planet on-time without damaging product quality.
A particular source of pride for FAMAGA is its team members, each of whom contributes to our work. We call into our team only experts, who already have experience in the direction of manufacturing equipment.
All spare parts from FAMAGA are affirmed - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been delivered, and this number is amounting every day. We are pleased that buyers choose FAMAGA again and again, and we are happy to make more advanced and technologically innovative industrial equipment so as stay in control.
To consult or order, call us by phone or write a message to the online chat on our official website. You can also forward a list of the necessary equipment to the email of our company - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 2 mm | |
Installation | flush | |
Assured operating distance | 0 ... 1.62 mm | |
Reduction factor rAl | 0.25 | |
Reduction factor rCu | 0.2 | |
Reduction factor r304 | 0.7 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) | |
Switching frequency | 0 ... 1000 Hz | |
Hysteresis | 0.01 ... 0.1 mm | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | &ge, 3 mA | |
Measuring plate detected | &le, 1 mA | |
Functional safety related parameters | ||
MTTFd | 11775 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
FM approval | ||
Control drawing | 116-0165 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0451 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) | |
Mechanical specifications | ||
Connection type | cable PVC , 75 mm , Wire ends, 3 mm, stripped and tin-plated | |
Core cross-section | 0.14 mm2 | |
Housing material | PBT | |
Sensing face | PBT | |
Degree of protection | IP67 | |
Cable | ||
Cable diameter | 2.6 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 2-V3-N ... | |
Effective internal capacitance | max. 40 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 2-V3-N ... | |
Effective internal capacitance | max. 40 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ 2-V3-N ... | |
Effective internal capacitance | max. 40 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 1D |