Inductive sensor NJ2-V3-N-0,075M Pepperl+Fuchs 250497
Inductive sensor NJ2-V3-N-0,075M Pepperl+Fuchs 250497

We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

NJ2-V3-N-0,075M 250497 Pepperl+Fuchs Inductive sensor

Manufacturer

Pepperl+Fuchs

Country

Germany

Name

NJ2-V3-N-0,075M

Part number

250497

Type

Inductive sensor

Description

Inductive sensor NJ2-V3-N-0,075M

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications NJ2-V3-N-0,075M 250497

If you are inspecting Pepperl+Fuchs NJ2-V3-N-0,075M 250497, reach FAMAGA, the world's top vendor of streamlined equipment. Our company has worked for more than ten years - these are ages of experience, which are outlined in the quality of products and particular attention to each buyer. We admire everyone, who collaborated with us - therefore, our regular purchasers get the most acceptable purchase conditions and discounts on the industrial equipment market. Nowadays, there are more than 3500 such customers, and we constantly make new agreements. More than 650 agreements are achieved per day, because FAMAGA delivers all over the earth . A well-built logistics connection and a partnership network cheer us to deliver our products anywhere in the planet on-time without damaging product quality.

A particular source of pride for FAMAGA is its team members, each of whom contributes to our work. We call into our team only experts, who already have experience in the direction of manufacturing equipment.

All spare parts from FAMAGA are affirmed - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been delivered, and this number is amounting every day. We are pleased that buyers choose FAMAGA again and again, and we are happy to make more advanced and technologically innovative industrial equipment so as stay in control.

To consult or order, call us by phone or write a message to the online chat on our official website. You can also forward a list of the necessary equipment to the email of our company - we will contact you ourselves with a worked out commercial proposal from FAMAGA.

Features NJ2-V3-N-0,075M 250497

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance2 mm
Installationflush
Assured operating distance0 ... 1.62 mm
Reduction factor rAl 0.25
Reduction factor rCu 0.2
Reduction factor r304 0.7
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 k&Omega,)
Switching frequency0 ... 1000 Hz
Hysteresis0.01 ... 0.1 mm
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected&ge, 3 mA
Measuring plate detected&le, 1 mA
Functional safety related parameters
MTTFd11775 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
EAC conformityTR CU 012/2011
FM approval
Control drawing116-0165
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0451
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated &le,36 V
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection typecable PVC , 75 mm , Wire ends, 3 mm, stripped and tin-plated
Core cross-section0.14 mm2
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Cable
Cable diameter2.6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Equipment protection level Ga
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNJ 2-V3-N ...
Effective internal capacitancemax. 40 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
Ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1.
Equipment protection level Gb
CE marking[*PD-Z02585A*]
ATEX marking II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNJ 2-V3-N ...
Effective internal capacitancemax. 40 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
Maximum permissible ambient temperatureDetails of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Equipment protection level Da
CE marking[*PD-Z02585A*]
ATEX marking II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions
Appropriate typeNJ 2-V3-N ...
Effective internal capacitancemax. 40 nF , a cable length of 10 m is considered.
Effective internal inductancemax. 50 µ,H , a cable length of 10 m is considered.
General information
Use in the hazardous areasee instruction manuals
Category1G, 2G, 1D