We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NCB10-30GM40-N0-10M-OG
Part number
242686
Type
Inductive sensor
Description
Inductive sensor NCB10-30GM40-N0-10M-OG
Stock availability:
On request
If you are questing Pepperl+Fuchs NCB10-30GM40-N0-10M-OG 242686, make contact with FAMAGA, the world's leading retailer of manufacturing equipment. Our company has functioned for more than ten years - these are ages of experience, which are described in the quality of products and personalseparate attention to each buyer. We understand everyone, who collaborated with us - thus, our regular consumers bring in the most flexible purchase conditions and discounts on the machine made streamlined equipment market. At this time, there are more than 4000 such customers, and we constantly sign new agreements. More than 650 affairs are settled per day, because FAMAGA delivers all over the world Germany, United Kingdom, Uganda, Syria, Angola, Morocco, Sudan, Eswatini, Myanmar, Ireland, Japan, Colombia, Malaysia, Gambia, Mauritania, United Arab Emirates, Albania, Latvia, Eritrea, Kenya, Thailand, Turkey, Haiti, South Sudan, Bolivia, Tanzania, Madagascar, Kyrgyzstan, Costa Rica, Slovakia, Pakistan, Suriname, Bangladesh, Jamaica, Malta, Dominica, Kiribati, Djibouti, Senegal, Comoros, Central African Republic, Luxembourg, East Timor, Belarus, Cyprus. A well-developed logistics chains and a partnership network allow us to send our units anywhere in the world promptly without discrediting product quality.
A special source of honor for FAMAGA is its employees, each of whom contributes to our work. We accept into our team only specialists, who already have experience in the field of factory-made equipment.
All merchandises from FAMAGA are verified - we are responsible for the cause of our work. Nowadays, more than 10 million units of products have been shipped, and this bulk is growing every day. We are proud that purchasers choose FAMAGA again and again, and we are eager to make more advanced and technologically modern industrial equipment so as stay in control.
To get some advice or book, contact us or write to the online chat on our official website. You can also dispatch a list of the required equipment to the email of corporation - we will contact you ourselves with a prepared commercial proposal from FAMAGA.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 10 mm | |
Installation | flush | |
Assured operating distance | 0 ... 8.1 mm | |
Actual operating distance | 9 ... 11 mm typ. | |
Reduction factor rAl | 0.32 | |
Reduction factor rCu | 0.32 | |
Reduction factor r304 | 0.72 | |
Output type | 3-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Switching frequency | 0 ... 650 Hz | |
Hysteresis | 1 ... 10 typ. 5 % | |
Reverse polarity protection | reverse polarity protected | |
Short-circuit protection | yes | |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Switching state indicator | LED, yellow | |
Functional safety related parameters | ||
MTTFd | 1870 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -25 ... 80 °C (-13 ... 176 °F) | |
Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Mechanical specifications | ||
Connection type | cable PUR (halogen-free) , 10 m , screened , Oil resistant , Flame-retardant as per IEC 60332-1 | |
Core cross-section | 2x 0.5 mm2 | |
Housing material | Stainless steel 1.4305 / AISI 303 | |
Sensing face | PBT | |
Degree of protection | IP66 / IP67 | |
Cable | ||
Bending radius | > 7.5 x cable diameter | |
Note | The shield is not connected to the sensor. | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB10-30GM...-N0... | |
Effective internal capacitance | max. 105 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , a cable length of 10 m is considered. | |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-significant identification is on the enclosed adhesive label | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB10-30GM...-N0... | |
Effective internal capacitance | max. 105 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. | |
Equipment protection level Gc (ic) | ||
Certificate | PF 13 CERT 2895 X | |
CE marking | [*PD-Z02586A*] | |
ATEX marking | II 3G Ex ic IIC T6&hellip,T1 Gc The Ex-significant identification is on the enclosed adhesive label | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ic Use is restricted to the following stated conditions | |
Effective internal capacitance | max. 105 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , A cable length of 10 m is considered. | |
Special conditions | ||
for Pi=34 mW, Ii=25 mA, T6 | 55 °C (131 °F) | |
for Pi=34 mW, Ii=25 mA, T5 | 55 °C (131 °F) | |
for Pi=34 mW, Ii=25 mA, T4-T1 | 55 °C (131 °F) | |
for Pi=64 mW, Ii=25 mA, T6 | 55 °C (131 °F) | |
for Pi=64 mW, Ii=25 mA, T5 | 55 °C (131 °F) | |
for Pi=64 mW, Ii=25 mA, T4-T1 | 55 °C (131 °F) | |
for Pi=169 mW, Ii=52 mA, T6 | 52 °C (125.6 °F) | |
for Pi=169 mW, Ii=52 mA, T5 | 52 °C (125.6 °F) | |
for Pi=169 mW, Ii=52 mA, T4-T1 | 52 °C (125.6 °F) | |
for Pi=242 mW, Ii=76 mA, T6 | 44 °C (111.2 °F) | |
for Pi=242 mW, Ii=76 mA, T5 | 44 °C (111.2 °F) | |
for Pi=242 mW, Ii=76 mA, T4-T1 | 44 °C (111.2 °F) | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NCB10-30GM...-N0... | |
Effective internal capacitance | max. 105 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 100 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G, 3G, 1D |