Description

Read/write head IUH-F190-V1-FR2-02

Stock availability:

On request

1007.48 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications 283538

The compact IUH-F190-V1-FR2-03 read/write head operates in the UHF frequency range and is optimized for use in industrial applications involving medium distances. The device reads and writes passive tags in line with EPC Generation 2 (ISO/IEC 18000-63). The read/write head can be used in China. The read/write head is compliant with the relevant transmission regulations. Wide range of options supported for filtering data. The read/write head is connected to the IDENTControl interface using an M12 connector. The user can monitor the status of the read/write head using the integrated LEDs. The read/write head has a typical detection range of around 2 meters, this range is determined by the tag used and can be adjusted by configuring the transmission power. Other influencing factors include the setup and installation of the specific application and the surrounding materials, particularly metal. The read and write distances for the relevant tag, which are detailed separately, have been established in a test laboratory under ideal conditions. For the actual read and write distances under real conditions, the combination of read/write head and tag must be tested in the desired application.

Features 283538

Product Description
Read/write head for IDENTControl, USA, Canada, Mexico, and Argentina
General specifications
Operating frequency902 MHz &hellip, 928 MHz: USA, Canada, Mexico, Argentina Transmission licenses for other countries on request
Emitted power3 &hellip, 1250 mW EIRP adjustable
Operating distancetyp. 2 m
UL File NumberE468231
Functional safety related parameters
MTTFd210 a
Indicators/operating means
LED greenPower on
LED yellowRead/write operation successful
LED blueTransmission mode
Electrical specifications
Current consumption&le, 450 mA
Power consumption&le, 9 W
Supplyfrom the IDENTControl
Surge protectioncategory 2
Standard conformity
Electromagnetic compatibilityEN 301489-1 EN 301489-3
Degree of protectionEN 60529
SafetyEN 62368-1
RFIDISO/IEC 18000-63
Approvals and certificates
FCC approvalThis device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC approvalThis device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Radio approvalUSA: FCC IREIUHF190V1B Canada: 7037A-IUHF190V1B
Ambient conditions
ClassificationEnvironmental condition A (controlled environment)
Ambient temperature-20 ... 70 °C (-4 ... 158 °F) (Operation with nontransmission periods, adjustable) -20 ... 60 °C (-4 ... 140 °F) (Continuous transmission mode)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Pollution degree2
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPA 6
Basediecast aluminum
Mass860 g