Type
Process Sensor
Description
GP-M001 Schlüsselvakuumsensor
Stock availability:
On request
If you are looking for Keyence GP-M001 , call FAMAGA, the world's primary distributor of factory-made equipment. Our company has worked for more than ten years - these are ages of experience, which are expressed in the quality of items and private attention to each customer. We cherish everyone, who conspired with us - so, our regular clients accept the most favorable purchase forms and discounts on the manufacturing equipment market. Nowadays, there are more than 4500 such consumers, and we constantly form new agreements. More than 650 affairs are settled per day, because FAMAGA operates all over the planet Germany, United Kingdom, Kazakhstan, Tajikistan, South Africa, India, Lesotho, Ukraine, Pakistan, Fiji, East Timor, Guyana, The Gambia, Slovenia, Nepal, Australia, Dominica, Liberia, Angola, Canada, Syria, Equatorial Guinea, Zimbabwe, Iraq, Sweden, Kyrgyzstan, Seychelles, Kuwait, Poland, Cameroon, Brunei, New Zealand, Cape Verde, Albania, Uruguay, Vietnam, El Salvador, Suriname, Belarus, North Korea, Benin, Ireland, Qatar, Estonia, Mauritius, Bangladesh, Panama, Burkina Faso. A well-built logistics link and a partnership network cheer us to dispatch our elements anywhere in the world on-time without damaging product quality.
A particular source of dignity for FAMAGA is its staff members, each of whom contributes to common cause. We request into our team only professionals, who already have experience in the field of industrial equipment.
All merchandises from FAMAGA are assured - we are responsible for the aftereffect of our work. Now, more than 10 million units of products have been provided, and this quantity is growing every day. We are proud that consumers choose FAMAGA again and again, and we are glad to make more developed and technologically advanced industrial equipment so as to stay on the top.
To get some advice or make a request, phone us or write a message to the online chat on our official website. You can also send a list of the necessary equipment to the email of organization - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
Model | GP-M001 | |
Rated pressure | -100 to +100 kPa (-1 to +1 bar) | |
Possible display range | -120.0 to +120.0 kPa (-1.200 to +1.200 bar) | |
Zero-cut pressure value | ±0.5% of F.S. | |
Burst pressure | 1.5 MPa (15 bar) | |
Display resolution | 0.1 kPa (0.001 bar) | |
Fluid type | Gas or liquid that will not corrode the liquid contact part | |
Type of pressure | Gage pressure | |
Precision | ±1.0% of F.S. or less*1 | |
Repeatability | ±0.3% of F.S. or less*2 | |
Temperature characteristics | ±0.6% of F.S./10°C | |
Connection diameter | G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.) | |
Box rotation angle | Maximum 330° | |
Medium temperature | -20 to +100°C (no freezing/condensation)*3 | |
Power supply voltage | 10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS | |
Current consumption | 50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4 | |
Display method | 4 column, digital LED, red/Vertical inversion display possible | |
Operation display light | Operation indicator (output 1) (orange), Operation indicator (output 2) (orange) | |
Hysteresis | During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis) During window mode: fixed (0.5% of F.S.) | |
Response | Control output | Selectable from 3 to 5000 ms |
Analogue output | As above + 2 ms (90% response) | |
Output | Output 1 control output | NPN/PNP open collector (Selectable), Max. 250 mA (30 V max) Main unit residual voltage 1 V max, N.O./N.C. selectable |
Output 2 replacement type | Control output | |
Analogue output | 4-20 mA, maximum load resistance 500 ? (When the electric voltage is more than 20 V)*5 | |
Environmental resistance | Enclosure rating | IP67 |
Pressure resistance | 400 kPa (4 bar) | |
Ambient temperature | -20 to +80 °C (No freezing and no condensation) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes) | |
Shock resistance | IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction) | |
Material properties | Port/diaphragm | Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM |
Other parts | Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass. | |
Applicable cable | M12 connector 4 pin | |
Weight | Approx. 150 g | |
*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C. *2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition. *3 When the temperature of the piping exceeds 80°C, do not connect the cable. *4 Consumption current including output is 0.6 A and under. *5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} ? When 23-30V: R = 622 ? |