Mounting bracket GL-R80H Keyence
Mounting bracket GL-R80H Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

GL-R80H Keyence Mounting bracket

Manufacturer

Keyence

Country

Japan

Name

GL-R80H

Type

Mounting bracket

Description

Sicherheitslichtvorhang 25mm Auflösungsvermögen/80 Strahlachsen/1625

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications GL-R80H

If you are pursuing Keyence GL-R80H , get in touch with FAMAGA, the world's top producer of machine made equipment. Our company has lasted for more than ten years - these are cycles of experience, which are depicted in the quality of goods and particular attention to each consumer. We cherish everyone, who joined with us - hence, our regular clients procure the most favorable purchase forms and discounts on the industrial equipment market. At this moment, there are more than 4500 such consumers, and we constantly arrange new agreements. More than 700 contracts are concluded per day, because FAMAGA operates all over the globe . A advanced logistics network and a partnership network guide us to dispatch our products anywhere in the planet with no delay without damaging product quality.

A specific source of good name for FAMAGA is its personnel, each of whom contributes to our work. We invite into our team only specialists, who already have experience in the range of machine made streamlined equipment.

All goods from FAMAGA are affirmed - we are responsible for the cause of our work. At this moment, more than 10 million units of products have been shipped, and this bulk is increasing every day. We are happy that consumers choose FAMAGA again and again, and we are happy to make more progressive and technologically innovative industrial equipment so as keep on top of it.

To request or make a request, call us by phone or write a message to the online chat on our official website. You can also direct a list of the required equipment to the email of corporation - we will contact you ourselves with a made commercial proposal from FAMAGA.

Features GL-R80H

Main Unit, Hand-protection Type, 80 Optical Axes
Model GL-R80H
Detection capability o25 mm
Beam axis spacing/Lens diameter 20 mm / o5
Detecting distance 0.2 to 15 m*1
Effective aperture angle Max. ±2.5° (When operating distance is 3 m or more)
Light source Infrared LED (870 nm)
Response time (OSSD) (ms) Wire synchronisation, One-line or Optical synchronisation system (Channel 0) ON>OFF 13.1
OFF>ON 58.4*2
All blocked>ON 89.1*3
Optical synchronisation system (Channel A or B) ON>OFF 19.2
OFF>ON 67.6*2
All blocked>ON 113.7*3
Detection mode Turns on when no interruptions are present in the detection zone
Synchronisation between the transmitter and receiver Optical synchronisation or Wire synchronisation (Determined by wiring)
Light interference prevention function Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically
Control output (OSSD output) Output 2 transistor outputs. (PNP or NPN is determined by the cable type)
Max. load current 500 mA*4
Residual voltage (during ON) Max. 2.5 V (with a cable length of 5 m)
OFF state voltage Max. 2.0 V (with a cable length of 5 m)
Leakage current Max. 200 µA
Max. capacitive load 2.2 µF
Load wiring resistance Max. 2.5 ?
Supplemental output (Non-safety-related output) AUX transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m)
Error output
Muting lamp output Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected.
External input When using a PNP output cable EDM input Wait input Reset input Muting input 1, 2 Override input ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)
When using an NPN output cable ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)
Rating Power voltage 24 VDC ±20%, ripple (P-P) 10% or less, Class 2
Power supply Current consumption (Max.) (mA) Transmitter 77
Receiver 87
Protection circuit Reverse current protection, short-circuit protection for each output, surge protection for each output
Approved standards EMC EMS IEC61496-1, EN61496-1, UL61496-1
EMI EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA
Safety IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998
Environmental resistance Enclosure rating IP65/IP67 (IEC60529)
Overvoltage category II
Ambient light Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less
Operating ambient temperature -10 to +55 °C (No freezing)
Storage temperature -25 to +60 °C (No freezing)
Operating relative humidity 15 to 85 % RH (No condensation)
Storage relative humidity 15 to 95 % RH
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Main unit case Aluminium
Upper case/lower case Nylon (GF 30%)
Front cover Polycarbonate, SUS304
Weight Transmitter 2230 g
Receiver 2240 g
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 1.0 m. *2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms. *3 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation, the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then determines the clear or blocked. *4 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA.