We are not the manufacturer, authorised distributor or authorised representative of the IFM brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are questing IFM SM8000, contact FAMAGA, the world's principle company of factory-made equipment. Our company has existed for more than ten years - these are ages of experience, which are represented in the quality of products and private attention to each client. We appreciate everyone, who engaged with us - hence, our regular consumers receive the most favorable purchase conditions and discounts on the manufacturing equipment market. Nowadays, there are more than 4000 such consumers, and we constantly sign new agreements. More than 750 agreements are achieved per day, because FAMAGA operates all over the world Germany, United Kingdom, Indonesia, Australia, Guatemala, Antigua and Barbuda, Dominican Republic, Rwanda, Cuba, Algeria, South Sudan, Nepal, Sudan, Paraguay, Qatar, Czech Republic, East Timor, Belarus, Zimbabwe, Dominica, Kiribati, China, Malaysia, The Bahamas, Austria, Bolivia, Nicaragua, Tanzania, Sweden, Suriname, Liechtenstein, Angola, Madagascar, Sierra Leone, Latvia, Senegal, El Salvador, Estonia, Egypt, Ireland, Jamaica, Cameroon. A well-elaborated logistics network and a partnership network cheer us to dispatch our items anywhere in the earth quickly without disreputing product quality.
A specific source of dignity for FAMAGA is its staff members, each of whom contributes to common cause. We request into our team only specialists, who already have experience in the field of machine made streamlined equipment.
All outcomes from FAMAGA are verified - we are responsible for the outcome of our work. At the moment, more than 10 million units of products have been provided, and this quantity is ascending every day. We are proud that consumers choose FAMAGA again and again, and we are eager to make more progressive and technologically advanced industrial equipment so as not to lower the bar.
To get some advice or make a request, get in touch with us or write a message to the online chat on our official website. You can also send a list of the needful equipment to the email of organization - we will contact you ourselves with a made commercial proposal from FAMAGA.
Application | |||||||||
---|---|---|---|---|---|---|---|---|---|
Application | Sum function, for general industrial use | ||||||||
Installation | pipe connection with adapter | ||||||||
Medium | Conductive liquids, Water, water-based liquids | ||||||||
Medium note |
| ||||||||
Measured medium temperature [°C] | -10…70 | ||||||||
Pressure strength [bar] | 16 | ||||||||
MAWP (for use according to CRN) [bar] | 11.2 | ||||||||
Electronic data | |||||||||
Operating voltage [V] | 18…30 DC, (according to EN 50178 SELV/PELV ) | ||||||||
Current consumption [mA] | 95, (24 V) | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] | 5 | ||||||||
Inputs/outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 2, Number of analog outputs: 1 | ||||||||
Inputs | |||||||||
Inputs | reset counter | ||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | Switching signal analog New signal, pulse signal, IO-Link, (configurable) | ||||||||
Electrical version | PNP/NPN | ||||||||
Number of digital outputs | 2 | ||||||||
Output signal function | normally open / normally closed, (parameterizable) | ||||||||
Max. voltage drop DC switching output [V] | 2 | ||||||||
DC switching output load current [mA] | 200 | ||||||||
Number of analog outputs | 1 | ||||||||
Analog current output [mA] | 4…20, (scalable) | ||||||||
Max. load [?] | 500 | ||||||||
Analog voltage output [V] | 0…10, (scalable) | ||||||||
Min. load resistance [?] | 2000 | ||||||||
Pulse output | Flowmeter | ||||||||
Short-circuit protection | yes | ||||||||
Short-circuit protection type | clocked | ||||||||
Overcurrent protection | yes | ||||||||
Measurement/setting range | |||||||||
Range measurements |
| ||||||||
Display range |
| ||||||||
Resolution |
| ||||||||
Setting point SP |
| ||||||||
Reset point rP |
| ||||||||
The starting point of the analog signal, ASP |
| ||||||||
Analogue end point, AEP |
| ||||||||
Width step |
| ||||||||
Momentary flow control | |||||||||
Pulse value | 0.00001 …100 000 m? | ||||||||
Pulse length [s] | 0.0025…2 | ||||||||
Temperature control | |||||||||
Measuring range [°C] | -20…80 | ||||||||
Resolution [°C] | 0.2 | ||||||||
Setting point SP [°C] | -19.2…80 | ||||||||
Reset point rP [°C] | -19.6…79.6 | ||||||||
Analog start point [°C] | -20…60 | ||||||||
Analogue end point [°C] | 0…80 | 0…80 | |||||||
In steps of [°C] | 0.2 | ||||||||
Accuracy/Uncertainty | |||||||||
Flow rate control | |||||||||
Accuracy (in measuring range) | ± (0.8 % MW + 0.5% MEW) | ||||||||
Repeatability | ± 0.2% MEW | ||||||||
Temperature control | |||||||||
Accuracy [K] | ± 2.5 (Q > 5 l/min) | ||||||||
Response Time | |||||||||
Flow Rate Control | |||||||||
Response time [s] | 0.15, (dAP = 0) | ||||||||
Programmable delay time dS, dr [s] | 0…50 | ||||||||
Switching output damping dAP [s] | 0…5 | ||||||||
Temperature control | |||||||||
Dynamics of response response T05 / T09 [s] | T09 = 20 (Q > 5 l/min ) | ||||||||
Software / Programming | |||||||||
Parameter selection | Flow rate control, flow meter, counter with presetting, Temperature control, hysteresis / window, normally open / normally closed, switching logic, current output / voltage output / pulse output, Start delay, display can be switched off, Display | ||||||||
Interfaces | |||||||||
Communication interface | IO-Link | ||||||||
Transmission method | COM2 (38.4 kBaud) | ||||||||
IO-Link test | 1.1 | ||||||||
SDCI standard | IEC 61131-9 | ||||||||
IO-Link Device ID | 575 / 00 02 3f | ||||||||
Profiles | Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis | ||||||||
SIO mode | yes | ||||||||
Desired port type | A | ||||||||
Analog operating data | 3 | ||||||||
Binary operating data | 2 | ||||||||
Min. cycle time [ms] | 5 | ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | -10…60 | ||||||||
Storage temperature [°C] | -25…80 | ||||||||
Degree of protection | IP 67 | ||||||||
Tests / approvals | |||||||||
EMC |
| ||||||||
Impact resistance |
| ||||||||
Vibration resistance |
| ||||||||
MTTF [g Code] | 145 | ||||||||
Pressure Equipment Directive | Good engineering practice, can be used for fluid group 2, group liquids 1 on request | ||||||||
Mechanical data | |||||||||
Weight [g] | 641.5 | ||||||||
Material | stainless steel steel (1.4404 / 316L), PBT-GF20, PC, FKM, TPE medium | stainless steel steel (1.4404 / 316L), PEEK, FKM | |||||||
Process connection | G 1 DN25 threaded connection Flat seal | ||||||||
Displays / Controls | |||||||||
Display |
| ||||||||
Notes | |||||||||
Notes |
| ||||||||
Pack quantity | 1 piece | ||||||||
electrical connection | |||||||||
Connection | Connector: 1 x M12, Contacts: gold-plated | ||||||||
Diagrams and Graphs | |||||||||
Pressure Loss | dP | Pressure loss | Q | volumetric consumption | |