IFM PN3094
  IFM PN3094

We are not the manufacturer, authorised distributor or authorised representative of the IFM brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

PN3094 IFM

Manufacturer

IFM

Country

Germany

Part number

PN3094

Description

Pressure sensor with display

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications PN3094

Programmable switching output with IO-Link and analogue output. Red/green display for clear identification of the acceptable range. The process connection can be rotated for optimum alignment. With long-term stability thanks to high overload protection. Robust design for use in harsh industrial environments.

Features PN3094

<± 0.1, (at temperature changes <10 K)
Application
Measuring elementCeramic capacitive pressure cell
FluidFluid group 2 in accordance with the Pressure Equipment Directive (PED)
Conditionally suitable for td>Liquid group 1 on request
Measured medium temperature [°C]-25…80
Pressure strength
75 bar1087 psi7.5 MPa
Min. burst pressure
150 bar2175 psi15 MPa
Vacuum resistance [mbar]-1000
Pressure typeRelative pressure
Electronic data
Operating voltage [V]18…30 DC, (according to EN 50178 SELV/PELV)
Current consumption [mA]<35
Min. insulation resistance [M?]100, (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]0.3
Built-in watchdogyes
Inputs/outputs
Number of inputs and outputsNumber of digital outputs: 1, Number of analog outputs: 1
Outputs
Total number of outputs2
Output signalSwitching signal, analogue signal, IO- Link, (configurable)
Electrical versionPNP
Number of digital outputs1
Output functionnormally open / normally closed, (parameterizable)
Max. voltage drop DC switching output [V]2.5
DC switching output load current DC [mA]150, (200 (…60 °C) 250 (…40 °C))
DC switching frequency [Hz]<170
Number of analog outputs1
Analog current output [mA]4… 20, (0 bar = 4 mA, 10 bar = 20 mA)
Maximum load [?]500
Analog voltage output [V]0…10, (0 bar = 0 V, 10 bar = 10 V)
Min. load resistance [?]2000
Short circuit protectionyes
Type of short-circuit protectionclocked
Overcurrent protectionyes
Measuring/setting range
Measuring range
-1…10 bar-14.5…145 psi-0.1…1 MPa
Setting point SP
-0.9…10 bar-13.5… 145 psi-0.09…1 MPa
Reset point rP
0.95…9.95 bar-14…144.5 psi> 0.095 MPa
Step to
0.05 bar0.5 psi0.005 MPa
Accuracy / error
Switch point error [% of span]<± 0.5
Repeatability [% of range]
Deviation from curve [% of span]<± 0.25 ( BFSL) / <± 0.5 (LS), (BFSL = Best Fit Straight Line, LS = Set Limit)
Hysteresis deviation [% of span]<± 0.25
Long-term stability [% of range]<± 0.05, (for 6 months)
Zero point temperature coefficient [% of measuring range / 10 K]0.2, (-25…80 °C)
Temperature coefficient range [% of measuring range / 10 K]0.2, (-25…80 °C)
Response time
Response time [ms]<3
Programmable delay time dS, dr [s]0…50
Switching output damping dAP [s]0…4
Analog output damping dAA [s]0…4
Max. analog output response time [ms]3
Software / Programming
Parameter SelectionHysteresis / Window, Normally Open / Normally Closed, On / Off Delay, Damping , Display, current output / voltage output
Interfaces
Communication interfaceIO-Link
Transmission methodCOM2
IO-Link test1.1
SDCI standardIEC 61131-9
IO-Link device ID431 d / 00 01 af h
ProfilesSmart Sensor: Process Data Variable, Device Identification, Device Diagnosis
SIO modeyes
Desired port typeA
Analog operating data1
Binary operating data1
Min. cycle time [ms]2.3
Operating conditions
Ambient temperature [°C]- 25…80
Storage temperature [°C]-40…100
Degree of protection IP 65, IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
DIN EN 61000-6-3
Impact resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10…2000 Hz)
MTTF [years]181
UL certification
UL registration numberJ004
Pressure Equipment DirectiveGood Engineering Practice
Mechanical Data th>
Weight [g]235.5
Materialstainless steel steel (1.4404 / 316L), PBT+PC-GF30, PBT-GF20, PC mediumstainless steel steel (1.4404 / 316L), Al2O3 (ceramic), FKM
Min. pressure cycles100 million
Tightening torque [Nm]25…35, (recommended tightening torque, V depending on lubrication, sealing and pressure rating)
Process connectionThreaded connection G 1/4 female thread M6 I
Built-in limiternone (can be modified)
Displays / Controls
Display
Display3 x LED, green (bar, psi, MPa)
Output status1 x LED, yellow
Measured valuesalphanumeric display, red /green 4-digit
Notes
Packing quantity1 piece
electrical connection
Connection Connector: 1 x M12, Contacts: gold-plated