We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CES-I-AR-U-C04-U05-119470
Part number
119470
Description
CES-I-AR-U-C04-U05-119470 Non-contact safety switches CES-I-AR-.-C04-..., flying lead
Stock availability:
On request
If you are inspecting Euchner CES-I-AR-U-C04-U05-119470 119470, reach FAMAGA, the world's leading retailer of streamlined equipment. Our company has progressed for more than ten years - these are years of experience, which are expressed in the quality of outcomes and individual attention to each user. We admire everyone, who cooperated with us - so, our regular clients accept the most acceptable purchase conditions and discounts on the factory-made equipment market. At present, there are more than 4 thousand such customers, and we constantly make new agreements. More than 600 purchases are terminated per day, because FAMAGA works all over the earth Germany, United Kingdom, Kenya, Bahamas, Macedonia, Botswana, Bolivia, Tajikistan, The Bahamas, Slovenia, Malta, Finland, Albania, Equatorial Guinea, Fiji, Brunei, Czech Republic, Yemen, Switzerland, North Korea, Monaco, Dominica, Egypt, South Sudan, Serbia, Samoa, Malaysia, Hungary, Belize, El Salvador, Ireland, China, Greece, Morocco, Laos, Central African Republic, Mozambique, Cape Verde, Panama, Vietnam, Sweden, Ghana, Indonesia, Georgia, Mauritania, Andorra. A well-built logistics link and a partnership network assist us to conduct our elements anywhere in the world immediately without undermining product quality.
A special source of pride for FAMAGA is its team members, each of whom contributes to common cause. We propose into our team only professionals, who already have experience in the direction of industrial equipment.
All merchandises from FAMAGA are ensured - we are responsible for the result of our work. At this moment, more than 10 million units of products have been shipped, and this amount is increasing every day. We are happy that users choose FAMAGA again and again, and we are happy to make more developed and technologically innovative industrial equipment so as to stay on the top.
To consult or place an order, phone us or write to the online chat on our site. You can also forward a list of the required equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
Designation | Function | Conductor coloring of connection cable |
---|---|---|
FI1B | Enable input for channel 2 | WH |
UB | Power supply, DC 24 V | BN |
FO1A | Safety output, channel 1 | GN |
FO1B | Safety output, channel 2 | YE |
OD | Monitoring output | GY |
FI1A | Enable input for channel 1 | PK |
0V | Ground, DC 0 V | BU |
RST | Reset input | RD |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing material | Plastic, PBT |
Weight | |
Net | 0,2 kg |
Ambient temperature | |
Cable static | -25 ... 65 °C |
Cable dynamic | -25 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.140 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.0,8 Nm |
Ready delay | 10 s |
Switching frequency | max.1 Hz |
Connection | connection cable PUR, length 5m |
Bending radius | |
static | 5 x cable diameter |
Dynamic | 10 x cable diameter |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV |
Current consumption | max.35 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | |
Single device | max.260 ms |
Delay per device | 5 ms |
Monitoring output OD | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Switching current | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs FO1A / FO1B | |
Test pulses | max.1,0 ms |
Test-pulse interval | min.140 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 200 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5V ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
Additional feature | Rubber support included |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Mission time | 20 |
Switch-on distance | |
Approach direction C or D (broad side) | 15 mm |
Approach direction A or B (front side) | 19 mm |
Assured operating distance Sao | |
Approach direction C or D (broad side) | min.10 mm |
Approach direction A or B (front side) | min.14 mm |
Switch-on distance | |
Approach direction C or D (broad side) | 11 mm |
Approach direction A or B (front side) | 15 mm |
Assured operating distance Sao | |
Approach direction A or B (front side) | 10 |
Approach direction C or D (broad side) | 6 |
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Switching hysteresis | min.1 mm |