We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.
If you are looking for Euchner CES-AP-C01-CH-SA-100250 100250, catch up with FAMAGA, the world's major distributor of manufacturing equipment. Our company has advanced for more than ten years - these are cycles of experience, which are outlined in the quality of spare parts and special attention to each buyer. We respect everyone, who conspired with us - so, our regular consumers accept the most beneficial purchase conditions and discounts on the factory-made equipment market. At present, there are more than 3500 such buyers, and we constantly form new agreements. More than 700 agreements are achieved per day, because FAMAGA works all over the globe Germany, United Kingdom, Philippines, Bahrain, Albania, Tanzania, Uzbekistan, Honduras, Argentina, Mozambique, Egypt, Belarus, Pakistan, Liberia, Macedonia, Oman, Sweden, Afghanistan, Poland, Mauritania, Benin, Fiji, Kyrgyzstan, Eritrea, Morocco, Denmark, Panama, Swaziland, The Gambia, Norway, Comoros, Kenya, Nicaragua, Thailand, Burkina Faso, Dominica, Switzerland, China, Zimbabwe, Vietnam, Uganda, Costa Rica, Cape Verde, Nepal, Namibia. A well-elaborated logistics chains and a partnership network allow us to send our elements anywhere in the globe immediately without compromising product quality.
A special source of honor for FAMAGA is its employees, each of whom contributes to our work. We invite into our team only professionals, who already have experience in the range of manufacturing equipment.
All items from FAMAGA are verified - we are responsible for the result of our work. Now, more than 10 million units of products have been supplied, and this amount is growing every day. We are pleased that clients choose FAMAGA again and again, and we strive to make more exceptional and technologically innovative industrial equipment so as to stay on the top.
To get some advice or order, phone us or write to the online chat on our site. You can also direct a list of the desirable equipment to the email of firm - we will contact you ourselves with a worked out commercial proposal from FAMAGA.
STATE | Status LED |
DIA | Diagnostics LED |
DIA | Diagnostics output (semiconductor) |
RST | Reset input |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
---|---|---|---|---|
1 | - | n.c. | WH | |
2 | UB | Power supply, DC 24 V | BN | |
3 | OA | Safety output, channel 1 | GN | |
4 | OB | Safety output, channel 2 | YE | |
5 | DIA | Monitoring output | GY | |
6 | - | n.c. | PK | |
7 | 0V | Ground, DC 0 V | BU | |
8 | RST | Reset input for hardware reset | RD |
Housing material | Plastic, PBT |
Weight | |
Net | 0,12 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting distance | min.40 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.1 Nm |
Ready delay | 0,5 s |
Switching frequency | max.1 Hz |
Connection | M12 plug connector, 8-pin |
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Reverse polarity protected, regulated, residual ripple < 5 %, PELV |
Current consumption | |
No load on outputs | max.50 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.400 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
Monitoring output DIA | |
Type of output | p-switching, short circuit-proof |
Switching current | max.200 mA |
Output voltage | 0,8 x UB ... UB V DC |
Safety outputs OA/OB | |
Test pulses | max.0,4 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 400 mA |
Output voltage | |
HIGH U(OA) / U(OB) | UB-1,5 ... UB V DC |
LOW U(OA) / U(OB) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 400mA |
Rated conditional short-circuit current | max.100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Repeat accuracy R | ? 10 |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.1 x 10-9 |
Mission time | 20 |
Switch-on distance | 22 mm |
Assured switch-off distance Sar | max.58 mm |
Assured operating distance Sao | min.18 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 18 mm |
Assured switch-off distance Sar | max.45 mm |
Assured operating distance Sao | min.15 mm |
Switching hysteresis | min.1 mm |
Switch-on distance | 27 mm |
Assured switch-off distance Sar | max.75 mm |
Assured operating distance Sao | min.20 mm |
Switching hysteresis | 3 mm |
Switch-on distance | 19 mm |
Assured switch-off distance Sar | max.45 mm |
Assured operating distance Sao | min.10 mm |
Switching hysteresis | min.1 mm |