Self-contained switch AMX5/12M COMITRONIC-BTI
Self-contained switch AMX5/12M COMITRONIC-BTI
Self-contained switch AMX5/12M COMITRONIC-BTI
Self-contained switch AMX5/12M COMITRONIC-BTI
Self-contained switch AMX5/12M COMITRONIC-BTI

We are not the manufacturer, authorised distributor or authorised representative of the COMITRONIC-BTI brand Worldwide. The private labels and part numbers shown on this website are the property of their respective owners.

AMX5/12M COMITRONIC-BTI Self-contained switch

Manufacturer

COMITRONIC-BTI

Country

France

Name

AMX5/12M

Category

Switches

Type

Self-contained switch

Description

Safety switch stand alone

Stock availability:

In stock

138 €

Need cheaper?

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications AMX5/12M

Controls the position of hazardous machine doors/cases with integrated self-checking Contactless coded sensor with electronic technology and relays IP68 PA6 / IP69K INOX316L Performance level and category without external controller: Cat 3 PL=d according to ISO 13849-1 Performance level and category with AWAX controller: Cat 4 up to PL=e Integrated safety level: SIL 2 according to IEC 61508

Level of performance without an external controller: PL = d
Level of performance with AWAX controller: up to PL = e
Safety category without an external controller: 3
Safety Integrity Level: SIL 2
Cycle after dangerous failure: B10d = 2,000,000 at 2A
Max. activation distance: 10 mm, 2 mm hysteresis
Security contacts / diagnostics AMX5 / AMX5CM12 : 2 x NO 2A / 48V redundant / 1 x PNP 250mA auxiliary
Security contacts AMX4: 2 x NO 2A/48V redundant
Security contacts / diagnostics AMX3 : 1xNO 2A / 48V redundant (2 series contacts) / 1xNF 250mA auxiliary
Detection encoding: mono-code inviolable
Indicator: LED indicates code recognition
Reset: automatic
Attachment: 4 tamper-proof M4 screws (optional ref: BH4)
Mounting position: 2 (double wall brackets)
Material: PA6 or INOX 316L mirror polished (AMX3-OX/AMX5-OX ?or PC (AMX5CM12)
Electrical Connection: 3, 6, 12m (UL2464 PVC) or 50cm cable with M12 connector (UL20549 PUR) (ref + MKT) or M12 metal base (AMX5CM12)
Water resistance: IP 68 (PA6) or IP 69K with stainless steel - new generation
Temperature: -25°C to +60°C
Marking: PA6 pad printing + serial number, INOX316L laser engraving with mechanically punched serial number for permanent traceability
Certification: TÜV Rheinland 01/205/5238/12
License Test Mark 968/EL 214.01/12

Features AMX5/12M

Power source
PELV/SELV IEC 60204-1
24 VDC -15% / +10% 12VDC - 15%/-10%
24 VAC -15% / +10% 50/60Hz
Current consumption 50 mA - 90 mA
Protection class Class II, pollution 3
Ambient temperature -25 °C / +60 °C
Protection class PA6 : IP 68 / 316L : IP 69K
Vibration resistance 10~55 Hz, 1.5 mm double amplitude
Shock resistance 10 g
Switching frequency < 2 Hz
Response time < 400 ms (Ton)
Risk duration < 15 ms (Toff)
Connecting line AC1-AC15-DC13 : 50 VAC/DC / 2 A working load and general use (5 VDC/10 mA minimum)
Auxiliary output NF : 24 V / 250 mA general use
Output diagnostics
Protection system
Internal fuse protection
Detection range
Transmitter/receiver
(IEC 60947-5-3)
Classification
Sn=12 mm (typical distance)
Sao=10 mm (guaranteed activation distance)
Sar=15 mm (guaranteed disengagement distance)
Hysteresis 2 mm, repeatability < 5%.
M3C25AU1
Weight PA6
Weight SS316L
12m: 810g
12m: 1075g