Specifications D3

  • Parallel display of differential pressure and head or system pressure in the display and two mA output interfaces
  • Electronic detection and digital transmission without capillaries
  • Detection and evaluation of temperature and pressure directly in the sensor stem: Extremely short response time, data output in real time, superior resistance to temperature shocks
  • Pressure sensor and electronics using digital signaling to avoid negative impact of temperature changes
  • Simple and reliable remote wire cable avoid frequent recalibration
  • Improved temperature compensation reduces errors in process temperature changes
  • Graphical user interface with intuitive settings
  • Integrated tank linearization and density compensation in the sensor
  • Integrated pressure compensation: Pressure values for 10 food types are already integrated, others can easily be added
  • Easy start of operation: “Plug and play” due to intuitive operation and simple selection of pre-defined parameters
  • Superior efficiency by reduced maintenance, avoidance of downtimes and higher degree of product utilization
  • Due to the modular design, components of the sensor can be replaced on site
  • Optionally one or two remote pressure sensors
  • Predefined and customized tank geometries and product properties adjustable
  • 2x standard 4 … 20mA interfaces incl. HART 7.0 communication
  • Measuring range from -1 … 35 bar
  • Total length between two pressure sensors up to 30m
Application examples:
  • Level measurement in pressurized vessels and tanks
  • Measurement in breweries lauter tun vessels
  • Measurement in sterile tanks in dairy

Features D3

Process ConnectionCLEANadapt | Dairy flange | DRD | SMS Liner | Tri-Clamp | CPM | Endress & Hauser Universal
Wetted materialStainless steel 1.4404 (316L) Ra≤0,8 μm | Diaphragm Stainless steel 1.4404 (316L), Ra≤0,64 μm
Measuring range0…0.4 | -1…2 | -1…7 | -1…35 bar
Accuracy± 0.15% of the calibrated range
Available versionsCompact | Remote
Temperature range process-18…110 °C
Temperature range CIP/SIP135 °C / max. 60 min.
Communication4…20 mA | HART 7.0
The values shown are the performance limits within the product line. The product-specific data for each individual configuration can be obtained from the product information